{"efta_number": "EFTA02467713", "page_count": 5, "url": "https://epstein-data.com/EFTA02467713", "pdf_url": "https://epstein-data.com/pdf/EFTA02467713.pdf", "pages": [{"efta_number": "EFTA02467713", "page_number": 0, "text_content": "From:\nSent:\nTo:\nSubject:\njeffrey E. <jeevacation@gmail.com>\nSunday, April 10, 2016 11:50 AM\nLarry Visoski\nRe: GIV update\nany issues with turning on wing heat at altitude?\nOn Sun, Apr 10, 2016 at 7:17 AM, Larry Visoski\n<mailto:\n> wrote:\nJeffrey\nMessage fr=m Pete,.below:\nDave and I are at airport no= in case you decide to depart earlier than 10am,, Plane is fuele= and ready,.\nFrom Pete:\nHello Jeffrey,\nLarry knows that I am long winded with my responses,<<span>\nHere is my brief-\nFeel free to read all at our leisure-\nThey are mostly my thoughts=so far-\nI suspect that the right precooler (fan air) modulating valve is bad=\nThey are both original.\nFrom the last vid=o and Photo's;\nEFTA_R1_01576797\nEFTA02467713\n", "char_count": 712}, {"efta_number": "EFTA02467713", "page_number": 1, "text_content": "The readings show that the left side is being given = voltage to the Torque motor sending a pressure to command the\nvalve =o be partially closed.\nZero volts, zero =ressure is for full open, ie: cold air into the precooler and lowering the=temperature into the supply\nsystem.\nThe =ignals show a steady state condition; 3 Volts, 3 PSI.\nThe valve has been sent signals, and has responded correctl=, and therefore is in the proper position to maintain 400\ndegrees in the s=pply system.\nThis is being monitored, an= controlled by the controller, and the sensor inputs.\nThere is no signal from the valve, the temperature monitoring circuit controls the changes required.\nThe right side shows that it is b=ing commanded to close due to the high voltage, and pressures.\n<= style=\"margin-top:0px;margin-bottom:0px\">(9 volts, 9 PSI)\n=t seems that the signals are not being followed, or that the valve cannot =espond to them.\nSince the control system does not see the temperature change from the sensors, it continues to increase the pressure\nto the valve.\nBrief complete-\nAs for the full version--/p>\nThis was done as a draft, please excuse any dup=ication for items noted in the brief, these were my original thoughts.\nI agree with all that you stated-\nThe guidelines are for what the electrical system does.\nWe have found a bad controller- the sweeping voltage and pressures, and -eplaced it-\nThere was also a bad sensor =hat was replaced-\n=span style=\"background-color:rgba(255,255,255,0)\">We have swapped the pr=ssure regulator/torque motors.\nEFTA_R1_01576798\nEFTA02467714\n", "char_count": 1567}, {"efta_number": "EFTA02467713", "page_number": 2, "text_content": "Latest sw=p was the Anticipators.\nThere seem to be-multiple issues, and we are narrowing them down.\nI believe that the electrical and control systems are now operatin= normally.\nNow on to the air side of it.=/span>\nF-om the last video, and photo's-\nI be=ieve that the left side is operating properly.\nThe Temp is being controlled by sending a regulated pressure to the =alve, and it responding.\nThe pressure su=plied is closing the valve, and maintaining the 400 Degrees requested.\nNo voltage equals no pressure, Valve open, I=wering the Temperature.\n<= style=\"margin-top:0px;margin-bottom:0px\">The right side shows giving a close signal to the pr=cooler (fan air) valve.\nHigh Voltage, an= pressure supplied to the Valve on that side to close, and increase the te=perature.\nThat side doesn't seem to =espond.\nThe valve has a 4 inch input/out=ut side.\nThe control line is about 1/4 i-ch.\nThat is one of the lines that we fou=d collapsed, and started us on this direction.\nIs it possible that the suppl= air is not being able to overcome the pressure at the valve?\nThe pressure read at the panel is a control pressure, also known as \"Muscle air\".\nMa-be the input air at the 4 inch diameter inlet, can overcome the control ai=.\nI again suspect an issue with the LP v=lve-\nThere is no valve position, or feedback signal from the valve-=/p>\n3\nEFTA_R1_01576799\nEFTA02467715\n", "char_count": 1368}, {"efta_number": "EFTA02467713", "page_number": 3, "text_content": "The electrical signal is showing to close the v=lve,\nThe pressure is also showing to c=ose the valve.\nOne way to check is to select Wing heat on-\nThe system causes the applicable side to remove the sign=ls, and allow the valves to go full open.\nWing heat is not normally used at altitude-\nWhen the aircraft is in below 0 degrees temps, there is no reason, sin-e any precip won't stick.\nAsk Larry =f there any issues with selecting the wing heat on at altitude-\n=p style=\"margin-top:0px;margin-bottom:0px\">I don't believe that there are any limits to th= altitude, but the fuel burn\nwill be increased.\nJust a quick check-</=>\nThe ground-checks for the precooler system are limited,\nEngines running, there should be no air flowing from the lower pylon heat exchanger at idle-\nIncrease power, an- there should be airflow noticed.\nMy tra=ning manual shows that the valve should start to open at about 74% HP on t-e ground,\nWing heat on, there should be =irflow.\nRegards,\nPete\nSent from my iPhone\n--=br>\n=AO please note\nEFTA_R1_01576800\nEFTA02467716\n", "char_count": 1045}, {"efta_number": "EFTA02467713", "page_number": 4, "text_content": "The information contained in this=communication is confidential, may be attorney-client privileged, mayconstitute\ninside information, and is intended only for the use of the addressee. It is the property of JEE Unauthorized use,\ndisclosure or copying of this communication or any part thereof is strictly prohibite= and may be unlawful. If you have\nreceived this communication in err=r, please notify us immediately by return e-mail or by e-mail to\njeevacation@gmail.com<=a>, and destroy this communication and all copies thereof, including all attachments.\ncopyright -all rights reserved\n5\nEFTA_R1_01576801\nEFTA02467717\n", "char_count": 621}]}