{"efta_number": "EFTA02408179", "page_count": 2, "url": "https://epstein-data.com/EFTA02408179", "pdf_url": "https://epstein-data.com/pdf/EFTA02408179.pdf", "pages": [{"efta_number": "EFTA02408179", "page_number": 0, "text_content": "To:\njeevacation@gmail.com[jeevacation@gmail.com]\nFrom:\nSent:\nSat 6/12/2010 4:36:38 PM\nSubject: G2 update\nJeffrey,\nI went this morning to brief the Avionics Manager at GD, Joe Higgins about our autopilot/seat belt ordinance\nchime.\nJoe is very knowledgeable in G2 avionics, He is busy with another aircraft that needs to be released today\naround 3pm, he will start our plane at that time or sooner.\nI have contracted Simuflite for assitance also, see emails below: I will keep you posted for further updates\nthanks\nLarry\nFrom: Steve White\nSent: Fri 6/11/2010 2:14 PM\nTo: Norm Thompson\nSubject: RE: Inverter Concerns\nI am teaching in France and have no Gulfstream schematics. The logic appears good but the E inverter needs to be used by itself if possible\nto check for a possible bus problem. The relay that feeds the Instrument Bus from the Main Bus also has a second separate sense relay that\nmight be intermittant. Our simplified schematic does not show this second sense relay. Also depending on ASC status, there is a third relay\ninvolved\ndepending on the brand of E inverter. I think it is ASC 20. This third relay helps keep the E inverter on line using the one particular brand\nof E inverter. This third relay may only work when the E inverter is selected on, not in normal operation. This is the best I can do from memory.\nSteve\nle of From: Norm Thompson\nSent: Friday, June 11, 2010 2:12 PM\nTo: Steve White; Paul Whitaker\nSubject: Inverter Concerns\nSteve / Paul,\nIf either of you might have any recommendations, I am sure our client would greatly appreciate\nyou assistance.\nV/r\nIf you just reply to me, I will forward to client. Thanks in advance.\nNorm Thompson\nGulfstream Instructor\nInfo from client:\nHi Norm,\nnice to hear from you,...\nSerial number 151 GIIB N909JE\nthis is what I have so far,\nthe Facts:\n-Instrument inverter bus light is flickering during flight\n-seat belt chimes for no reason during flight, (is this DC powered or AC) what BUS powers seat belt\nchime?\nEFTA_R1_01467802\nEFTA02408179\n", "char_count": 2009}, {"efta_number": "EFTA02408179", "page_number": 1, "text_content": "-auto pilot kicks off randomly, even when light does not flicker on INST INV BUS...\n-normal system operation is \"A\" inverter (2500va) powers, \"Main Inverter BUS\", and Main inverter \"bus\"\npowers Instrument Inverter BUS with a back up of small E inverter (only 500va),\n-there is one relay that I see in the schematic that controls switch ology for the MAIN INVERTER BUS\nto the INSTRUMENT INVERTER BUS, since its the INST INV BUS is flashing now, I think the culprit is\nthe \"INSTRUMENT BUS CONTROL RELAY\" this is the only relay that comes between Main inverter bus\npower and the Instrument INV BUS, \"A\" inverter is powering the MAIN bus, plus powers INST INV BUS,\nwith a back up power for INST INV BUS is \"E\" inverter, the only thing to cause this instrument bus to\nflash would be an A inverter problem, but that would cause the MAIN INVERTER BUS to flicker also, I'm\nonly getting the INSTRUMENT BUS light flickering, so I think its the INSTRUMENT BUS CONTROL\nRELAY this time.\nthanks,\nLarry\nEFTA_R1_01467803\nEFTA02408180\n", "char_count": 1018}]}