{"efta_number": "EFTA01454635", "page_count": 1, "url": "https://epstein-data.com/EFTA01454635", "pdf_url": "https://epstein-data.com/pdf/EFTA01454635.pdf", "pages": [{"efta_number": "EFTA01454635", "page_number": 0, "text_content": "RRP72 - Southern Financial\nAppendix F: Comparing CO2 Savings from Retrofit\nProjects and New Green Building Construction\nDescription\nCapital Cost\nAnnual CO₂ Savings¹\n# of Projects at\n$300m of Investment\nRetrofit Project\nEnergy savings upgrades to individual buildings -\nall capital deployed is focused on energy saving\nmeasures\nDeep retrofits targeting approximately 25% whole\nbuilding energy savings across a range of building\nsystems, including heating, cooling, lighting, and\ncontrols\n$3.2m for \"typical\" project in 600,000 square foot\noffice building\n3,100 to 4,200 tons per year for each project vs.\nhistorical baseline\n105 (assuming entire portfolio is typical project)\nTotal Annual CO₂\nSavings¹\n310,000 to 420,000 tons per year\nW\nM\nM\nNew Construction of Net Zero Green Building\nThe new \"Bullitt Center\" as a reference point for one of the\ngreenest, true \"net-zero\" green buildings in the world\nThe \"Bullitt Center\" is entirely off the utility grid and\nproduces energy on-site. It is expected to be responsible\nfor zero carbon emissions annually due to its use of\nrenewable energy and super-efficient construction\nMore information can be found at:\nhttp://en.wikipedia.org/wiki/Bullitt Center\n$30m for all costs except tenant fit-out (included\nconstruction and land) for 58,000 square foot office\nbuilding\n~1,215 tons per year vs. standard building\n10 buildings can be built for same amount as total capital\nexpected to be deployed by the Partnership\n12,150 tons per year\n25-35x the impact on CO2 savings from retrofit projects vs. best in class green construction\non a dollars invested basis¹\n* DOE CBECS 2003, Team analysis; Annual savings calculated on a per-project basis assuming a project size of between $2 and $5 million and a project profile generally consistent with the type of\nproject being targeted by the Partnership;\nNote: This analysis is based entirely on publicly available information about the Bullitt Center project, and has not been independently verified by Deutsche Asset & Wealth Management. Although\nthe Team believes that retrofit projects will result in some level of carbon reduction, there can be no assurance regarding the amount of carbon reduction that will result from a particular project or the\nprojects as a whole. In evaluating and structuring each project, the Partnership will focus exclusively on the return aspects of the project and not the project's ability to reduce carbon. For example,\nif a particular project could be structured in two alternative ways, one that generated a higher return and resulted in less carbon reduction, and another that generated a lower return but resulted in\nmore carbon reduction, the Partnership would pursue the former and not the latter structure.\nDeutsche Asset\n& Wealth Management\nRREEF Retrofit Partners, L.P. For U.S. Person Clients of the U.S./Americas Key Client Partners Desk Only\nJune 2014\nCONFIDENTIAL - PURSUANT TO FED. R. CRIM. P. 6(e)\nCONFIDENTIAL\nDB-SDNY-0112891\nSDNY_GM_00259075\nEFTA01454635\n", "char_count": 2989}]}