{"efta_number": "EFTA01224546", "page_count": 24, "url": "https://epstein-data.com/EFTA01224546", "pdf_url": "https://epstein-data.com/pdf/EFTA01224546.pdf", "pages": [{"efta_number": "EFTA01224546", "page_number": 0, "text_content": "SOFTWARE House\nFrom Tyco Security Products\n6 Technology Park Drive\nWestford, MA 01886-3140\nFax: 978-577-4392\nPhone: 978-577-4000\nC•CURE 9000 UL Addendum\nC-CURE 9000 System\nVersion 2.50\nUL Addendum\n8200-1188-01\nRevision AO\nEFTA01224546\n", "char_count": 235}, {"efta_number": "EFTA01224546", "page_number": 1, "text_content": "C•CURE and Software House are registered trademarks of Tyco Security Products.\nThe trademarks, logos, and service marks displayed on this document are registered in the United\nStates [or other countries]. Any misuse of the trademarks is strictly prohibited and Tyco will\naggressively enforce its intellectual property rights to the fullest extent of the law, including\npursuit of criminal prosecution wherever necessary. All trademarks not owned by Tyco are the\nproperty of their respective owners, and are used with permission or allowed under applicable\nlaws.\nProduct offerings and specifications are subject to change without notice. Actual products may\nvary from photos. Not all products include all features. Availability varies by region; contact\nyour sales representative.\nC•CURE 9000 System Version 2.50\nPart Number: 8200-1188-01\nRevision Number: A0\nRelease Date: December 2015\nThis manual is proprietary information of Software House. Unauthorized reproduction of any\nportion of this manual is prohibited. The material in this manual is for information purposes\nonly. It is subject to change without notice. Software House assumes no responsibility for\nincorrect information this manual may contain.\n© 2015 Tyco Security Products\nAll rights reserved.\nii\nC•CURE 9000 UL Addendum\nEFTA01224547\n", "char_count": 1300}, {"efta_number": "EFTA01224546", "page_number": 2, "text_content": "OVERVIEW\nThis addendum provides UL requirements for C•CURE 9000 system components. All other\nC•CURE 9000 documentation is supplemental only and has not been evaluated by UL.\nGENERAL REQUIREMENTS\nUL approved installations must conform to the following general requirements:\n⚫ The System must be installed indoors within the protected premise, wired in accordance\nwith the National Electrical Code (NFPA70) and the local authorities having jurisdiction.\n•\n•\n•\n•\nAll devices must be UL Listed and, where applicable, powered by UL Listed access\ncontrol or burglar alarm power-limited power supplies capable of up to 24 hours of\nstandby power or 4 hours backup power with notification.\nAll cabling and wiring used must be UL Listed and/or Recognized and suitable for the\napplication.\nUnless otherwise noted, all external connections used (relays, battery wires, power supply\nwires, etc.) must be connected to power limited circuits only.\nThe following features MUST be disabled for UL installations: suppress read misread,\nsuppress reader misread and non alarm input report flag.\n⚫ The following features MUST be enabled for UL installations: event beep.\nNOTE: System components, functions, and features not specifically included in this addendum\nare untested or do not conform to UL requirements.\nHARDWARE CONFIGURATION REQUIREMENTS\nSupply Line Transient Protection\nAll supply lines must be protected by a transient protection device that complies with the\nStandard for Transient Voltage Surge Suppressors, UL 1449, with a maximum marked rating of\n330V. This includes the AC power lines for all C•CURE 9000 equipment such as client and\nserver computers; network hubs, routers, and bridges; terminal servers; leased-line modems; and\nprotocol converters. Excluded from this requirement are apC/8X panels, iSTAR controllers,\nDMP panels and periphery equipment such as RM Readers, RM-4, RM-4E, R8, 18 and 1/8 CSI\nboards.\nSignal Line Transient Protection\nShall comply with the standard for protectors for data\n... [truncated, 2122 chars — for the full page use /api/corpus/document/EFTA01224546/2 or ?id=EFTA01224546&page=2]", "char_count": 2122}, {"efta_number": "EFTA01224546", "page_number": 3, "text_content": "Signal line transient protection devices are not required for readers or input devices connected to\nan apC/8X panel, iSTAR controller, DMP panel, RM Readers, RM-4, RM-4E, R8, 18 and 1/8\nCSI boards.\nCommunication Circuits and Network Components\nAll communication circuits and network components connected to the telecommunications\nnetwork must be protected by a transient protection device that complies with the Standard for\nSecondary Protectors for Data Communication Circuits, UL 497A. These protectors shall be\nused only on the protected side of the telecommunications network. This includes the TCP/IP\nnetwork and serial data lines for all C•CURE 9000 equipment, such as client and server\ncomputers, network ports and server serial ports. Excluded from this requirement are the data\nlines that feed directly into apC/8X panels, iSTAR controllers and DMP panels.\nTemperature Controlled Environment\nThe C•CURE 9000 server computer must be installed in a temperature-controlled environment\nthat is maintained by the HVAC system to be in the range of 13-35°C (55-95°F). The HVAC\nsystem must be provided with at least 24 hours of standby power supplied by an engine-driven\ngenerator or standby battery. Excluded from this requirement are apC/8X panels, iSTAR\ncontrollers, DMP panels and periphery equipment, such as RMS and 1/8 boards.\nBackup System\nThe C•CURE 9000 server computer must be completely duplicated with provision for\nswitchover to the backup system within 30 seconds. The backup system shall be fully operational\nwithin 6 minutes of the loss of the primary system. This allows 30 seconds for the backup system\nto be fully energized and connected to necessary communication lines and other devices,\nfollowed by 5-1/2 minutes for the system to boot up, conduct memory tests, file system check,\nsecurity verifications and prepare for full system operation. The backup computer shall have the\ncapabilities of the primary, such as memory, speed and the like.\nThe backup system may be provided\n... [truncated, 2902 chars — for the full page use /api/corpus/document/EFTA01224546/3 or ?id=EFTA01224546&page=3]", "char_count": 2902}, {"efta_number": "EFTA01224546", "page_number": 4, "text_content": "GROUNDING\nAll equipment shall be properly grounded according to the hardware's installation instructions.\nCabinet Tamper Detection Inputs\nThe C•CURE 9000 supports inputs that detect cabinet tamper for apCs, iSTARS, DMP panels\nand RM readers. All apCs, iSTARS, DMP panels and RM readers must be configured to detect\ncabinet tamper. Each tamper input must specify that an event be triggered when the device is\ntampered. This event must be configured to always be armed, on-line, annunciated, and require\nacknowledgement.\nAC Power Fail Inputs\nThe C•CURE 9000 supports inputs that detect AC power fail for apCs, iSTARS and DMP panels.\nAll apCs, iSTARS, and DMP panels must be configured to detect AC power fail. Each AC power\nfail input must specify that an event be triggered when the controller loses AC power. This event\nmust be configured to always be armed, on-line, annunciated, and require acknowledgement.\nEvent Association with Communications Failure\nThe C•CURE 9000 supports the association of events with controller and reader communications\nfailure. Each apC, iSTAR, and RM reader must be configured to trigger an event when the\ndevice goes into communications failure. This event must be configured to always be armed, on-\nline, annunciated, and require acknowledgement.\nSupervised Inputs\nSupervised inputs must be used for UL1076 applications. The C•CURE 9000 supports\nsupervised inputs located on apCs, iSTARS, DMP panels and 1/8 boards.\nEach supervised input must be configured to trigger an event when the input is activated and a\nsupervision error is detected for the input. These events must be configured to always be armed,\non-line, annunciated, and require acknowledgement.\nNOTE: See individual panel installation instructions for panel-specific End of Line (EOL)\nsupervision requirements and specification.\n3\nC-CURE 9000 UL Addendum\nEFTA01224550\n", "char_count": 1865}, {"efta_number": "EFTA01224546", "page_number": 5, "text_content": "MONITOR POINTS\nDescription\nMonitor points are alarm devices connected to input circuits.\nEach monitor point functions independently and does not interfere with operation of the others.\nThe hardware modules monitor the supervised inputs. The following states are reported:\n⚫ Secure, Alert, Shorted, Open, and Line Fault\nThe configuration in the host computer determines how the hardware module and the reporting\nsoftware will respond to the various conditions that are detected.\nUL Compliant Supervision\nThe indication of whether a monitor point is Normally Closed (NC) or Normally Open (NO) is\ndone by how the resistor network is wired in conjunction with the alarm device to form a\nsupervised End Of Line (EOL) resistor alarm zone. The host system views monitor points as\nbeing either logically true or false. Software House wires NO and NC supervised input circuits\ntwo ways because it makes the software implementation more logical.\nThe two different methods result in an alarm loop resistance of 1K ohms being the Secure\nsupervised state whether the monitor point is connected as a NO or NC alarm loop. Since the\nhardware wiring defines NO and NC, the software works with inputs that are simply either\nlogically true or false.\nWiring for Alarm Zones\nTo wire a NO alarm loop to an input circuit, connect a 1 KQ EOL resistor across the input and\nanother EOL in series with the switch, as shown below. This circuit will provide 5-state\nsupervision.\nAssignment of Priorities to Events\nThe C•CURE 9000 supports assigning priorities to events. If this feature is used, the order of\npriority must be as follows from highest to lowest:\n1. Industrial supervision where a risk of injury to person or damage or destruction of property\nmay be involved\n2. Hold-up (Robbery) or panic alarm\n3. Burglar alarm\n4. Watchman tour\n5. Fire alarm supervision error\n4\nC•CURE 9000 UL Addendum\nEFTA01224551\n", "char_count": 1885}, {"efta_number": "EFTA01224546", "page_number": 6, "text_content": "6. Burglar alarm supervision error\n7. Industrial supervision where a risk of injury to person or damage or destruction of property\nwill not be involved\n8. Other supervisory services\nNOTE: Items 2 and 3 may have equal priority; items 5 and 6 may have equal priority; and items\n7 and 8 may have equal priority.\n5\nC-CURE 9000 UL Addendum\nEFTA01224552\n", "char_count": 348}, {"efta_number": "EFTA01224546", "page_number": 7, "text_content": "OPERATIONAL REQUIREMENTS\nOperation/Testing\n1. Readers are tested by reading a sample card and observing the results on the Monitoring\nStation application. If the reader and card formats are properly set, an \"access granted\" or\n\"access denied\" message appears on the screen. A \"card misread\" message indicates that the\nreader is not properly installed or the card format does not match the settings in the C•CURE\n9000 Administration application.\n2. Inputs are tested by opening/closing (activating/deactivating) the device. Input devices must\nhave the proper supervision resistors installed to function with C•CURE 9000. When inputs\nare working properly, you see the messages \"input xxx activated\" and \"input xxx\ndeactivated. Shorting or opening the cable is indicated as \"input xxx shorted\" or \"input xxx\nopen loop\" on the Monitoring Station application.\n3. Outputs are tested by performing a manual action in the Monitoring Station application. You\ncan momentary open a door or activate any other relay. You can then use a resistance meter\nto determine if the relay contacts close and open properly.\nMaintenance\n⚫ For electronic modules exposed to high dust environments: Check the assemblies for\nexcess dust build-up every 6 months and remove the dust and dirt from the assemblies\nwith forced air.\n•\nFor readers exposed to external weather conditions: Check the enclosure sealing for\nleaks at 6-month intervals. If the seal is not intact, replace the gasket\n6\nC•CURE 9000 UL Addendum\nEFTA01224553\n", "char_count": 1499}, {"efta_number": "EFTA01224546", "page_number": 8, "text_content": "Recommended PC Configuration for C•CURE 9000\nServer and Client PCs must be UL Listed (NWGQ), (Series L-N) Intel Pentium Core or greater\n(Series P-S) Quad Core Intel Xeon or greater with the following specifications:\nCPU\nRAM Disk\nO/S\nMAS\nXeon Quad\nCore E5-\n16 GB Dual 600 GB\n≥15K RPM\nWin Server\n2450 or\ngreater\n≥ 2.1 GHz\nSQL\n2008 R2 SP1\n(Standard/Ent)\n64-bit\nWin Server\n2012 R2\n(Standard)\n64-bit\nSQL Server 2008 R2 SP2\n(Standard/Ent)\n64-bit\nSQL Server 2012 SP2\n(Standard/Ent)\n64-bit\nSAS (P-S)\nXeon Quad\nCore E3-\n16 GB Dual 300 GB\n≥ 15K RPM\nWin Server\n1240 or\ngreater\n≥ 3.3 GHz\nC-CURE 9000 UL Addendum\n2008 R2 SP1\nSQL Server 2014\n(Standard/Ent)\n64-bit\nSQL Server 2008 R2 SP2\n(Standard/Ent)\n(Standard/Ent) 64-bit\n64-bit\nWin Server\n2012 R2\n(Standard)\n64-bit\nWin7 SP1\nSQL Server 2012 SP2\n(Standard/Ent/Express)\n64-bit\nSQL Server 2014\n(Standard/Ent/Express)\n64-bit\nPro/Ent\n64-bit\nWin 8.1 SP1\n(Pro/Ent)\n64-bit\n7\nEFTA01224554\n", "char_count": 918}, {"efta_number": "EFTA01224546", "page_number": 9, "text_content": "SAS (L-N)\nIntel 3rd\n8 GB\nDual 80 GB\nWin Server\n≥ 7200 RPM\nGeneration\nCore i7-3770\nor greater\n≥ 8MB\nClient\nIntel Core\n4 GB\n500 GB ≥\ni5-3470 or\non\n7200 RPM\ngreater\n32-bit\n≥ 3.2 GHz\n8 GB\non\n≥ 6MB\n64-bit\n2008 R2 SP1\nSQL Server 2008 R2 SP2\n(Standard/Ent)\n(Standard/Ent) 64-bit\n64-bit\nWin Server\n2012 R2\n(Standard)\n64-bit\nWin 7 SP1\nPro/Ent\n64-bit\nSQL Server 2012 SP2\n(Standard/Ent/Express)\n64-bit\nSQL Server 2014\n(Standard/Ent/Express)\n64-bit\nWin 8.1 SP1\n(Pro/Ent)\n64-bit\nWin 7 SP1\n(Pro/Ent)\n(32 or 64-bit)\nWin Server\n2008 R2 SP1\n(Standard/Ent)\n64-bit\nWin 8.1 SP1\n(Pro/Ent)\n(32 or 64-bit)\nWin Server\n2012 R2\n(Standard)\n(64-bit)\nN/A\nvictor\nUnified\nIntel i5-4570\n16 GB 240 GB\nWindows 7\nEmbedded,\nSQL Server 2012 SP2\nStandard/Ent/Express (32 or\nSiteServer 3.2 GHz\n4 or 6 TB\n(Storage)\n(Standard)\n64-bit)\n64-bit\nQuad-Core\nNOTE: All computers used in the C•CURE 9000 System must be UL Listed.\nInstallation Locations\nThe system must be installed within the protected premise and wired in accordance with the\nNational Electrical Code (NFPA 70), and the local authorities having jurisdiction.\nNOTE: The hardware comprising this system is not for outdoor use except the RM1, RM2, and\nRM2 readers. In an outdoor application or when the temperature is expected to drop below 40°F,\nthese readers must be configured with gasket and an optional heater kit\n(P/N 130-915) for use in a 115 VAC installation only.\n8\nC•CURE 9000 UL Addendum\nEFTA01224555\n", "char_count": 1428}, {"efta_number": "EFTA01224546", "page_number": 10, "text_content": "C•CURE 9000 FEATURES\nTable 2 shows the features and whether or not they were evaluated by UL.\nTable 2. Features Evaluated by UL\nFeature\nUL\nEvaluated\nEnterprise Architecture option\nYes\nDatabase Synchronization\nGlobal Objects\nCentral Reporting\nDynamic Views/Queries/Reports\nApplication Server Editor\nCentral Monitoring\nYes\nYes\nYes\nYes\nYes\nYes\nSynchronization of Journal and Audit\nYes\nGlobal System Variables\nYes\nEditing objects on remote servers\nYes\nGlobal Personnel-related or Operator-related objects\nYes\nReport on personnel with access to a door\nYes\nElevator Swipe and Show\nYes\nCard Admit and Reject Activity Viewer Options\nYes\nRemove Clearances menu selection\nYes\nEvent/Alarm Monitoring\nYes\nDoor Control\nYes\nElevator Control\nSchedules\nTime Zone Management\nOperator Privileges\nNo\nYes\nYes\nYes\nCard Record Definitions\nYes\nCard Format Definitions\nYes\nDatabase Partitioning\nYes\nAutomated Personnel Data Import\nYes\nClearances\nYes\nC•CURE 9000 UL Addendum\n9\nEFTA01224556\n", "char_count": 965}, {"efta_number": "EFTA01224546", "page_number": 11, "text_content": "Feature\nReports\nAudit Trail\nActivity Monitoring\niSTAR Panel Support\nUL Tested\nYes\nYes\nYes\nNo\nPaging and E-mail\nNo\nClosed Circuit Television Integration (CCTV)\nNo\nCardholder Access Events\nYes\nRedundancy Qualification (everRun MX, everRun Enterprise)\nYes\niSTAR Configurable Activity Buffer Size Enhancement\nYes\nEncryption Box Qualification\nYes\nAudit Trail of Security Objects\nYes\nEvent Triggered Database Backup (on iSTAR)\nYes\nEnhanced Partitioning\nYes\nMultiple Cards per cardholder\nYes\n256-bit card numbers\nNo\n128 total card formats\nNo\nNet Vue Presets and Patterns Enhancement\nYes\niSTAR Reader LED and beep patterns\nYes\nAdditional user-named fields\nYes\nPIN-only access\nYes\nHolidays\nYes\nLDAP Import of Personnel Records\nNo\nRole Based Clearances\nYes\nRole Based Clearances\nYes\nDouble Swipe\nNet Vue Alarm Management\nNetVue Popup Window\nIntegration with Video Edge NVR System\nPreset Log Messages\nLong Term Comm. Loss Functionality\nYes\nYes\nYes\nNo\nYes\nYes\n10\n10\nC•CURE 9000 UL Addendum\nEFTA01224557\n", "char_count": 991}, {"efta_number": "EFTA01224546", "page_number": 12, "text_content": "Feature\niSTAR eX 8 Readers\nRole Support with Import of Personnel\nAutomated Import of Personnel Records\nSupport of apC Panels\nUL Tested\nYes\nYes\nNo\nYes\nC•CURE Mobile\nNo\nWireless Access System\nNo\nDouble Swipe with Triggers\nYes\niSTAR Clusters\nYes\nRefresh of Live Displays after communication loss and restore\nYes\nSpecialized Security Limited Functionality (SSLF)\nNo\nImport/Export Enhancements\nNo\nVista Support for Client Applications\nYes\nIntellex 5.0\nNo\nVideoEdge 4.7.1\nNo\nHardware Drivers as Window Services\nNo\nExport Selection to CSV from Dynamic Views and Query Results\nYes\niSTAR Cluster based Antipassback and Time Antipassback\nYes\nC•CURE ID 3.1\nYes\nSmartcard Programming and Enrollment\nYes\niSTAR Intrusion Zones\nYes\nKeypad Commands\nYes\nReport Performance Improvements\nYes\nClient/Server Encryption\nYes\nC•CURE Encryption Engine 1.0\nYes\niSTAR Edge Support\nYes\nC•CURE 800 Field Compatibility\nYes\nWeb Client\nPersonnel View\nUser Defined Fields\nArea Phase 2\nNo\nYes\nYes\nYes\nC-CURE 9000 UL Addendum\n11\nEFTA01224558\n", "char_count": 1007}, {"efta_number": "EFTA01224546", "page_number": 13, "text_content": "12\nFeature\nUL Tested\nOccupancy restriction\nYes\nN-Man rule\nYes\nManual Action Challenge\nYes\nRM LCD Messages\nYes\nClearance Filters\nYes\nHoliday Schedule Enhancement\nYes\niSTAR FAI support\nYes\niSTAR Edge 4-reader model\nYes\niSTAR Edge Dual Range - added SWH Dual 1K NO/NC selection to\nlist of supported EOL circuit types on the controller's General tab.\nYes\nFlexNet Licensing\nYes\nGlobal Antipassback\nArea Lockout\nArea Demuster\nYes\nYes\nYes\nEscorted Access\nYes\nDMP XR500E Panels\nYes\nDMP XR500N Panels\nYes\nDMP XR100N Panels\nYes\napC Time Zones\nYes\niSTAR Ultra\nYes\nInactivity Card Deactivation\nYes\nIndividual Card Access Events\nYes\nFirst/Last Card Read Report\nYes\nCustom Clearances\nYes\nLatch/Unlatch/Toggle/Pulse Event\nYes\nWeb Client Portraits and Acknowledgement\nYes\nJournal Triggers\nYes\nEncryption Enhancements\nNo\n⚫ iSTAR Pro AES Encryption\nFIPS 140-2 Algorithm Updates\nC•CURE 9000 UL Addendum\nEFTA01224559\n", "char_count": 897}, {"efta_number": "EFTA01224546", "page_number": 14, "text_content": "Feature\nGuard Tour\nAdvanced Door Monitoring\nDual Phase Acknowledgement\nAssigning Privilege Groups to Operators\nSchlage Wireless Lock support on iSTAR Controllers\nDynamic Area Management and Conditional Access\nVisitor Management Portal\nPersonnel Pin Exempt (ADA)\nMulti-version Enterprise Sync\nSupport of IP-ACM controller module\nSupport of RM2-4000-PI26 and RM2L-4000-PI26 Readers\niSTAR Ultra SE (Pro Mode)\niSTAR Ultra SE (Ultra Mode)\nDial-up controller support\nUL Components\nThe following system components meet UL requirements.\nUL Tested\nYes\nYes\nYes\nYes\nYes\nYes\nYes\nYes\nYes\nNo\nYes\nYes\nYes\nNo\nUL Evaluated Panels\nPanel\nFirmware\nComments\napC/8X\n8.7Zx\nNone\niSTAR-Pro\n5.2.x\nNone\niSTAR- eX\n6.x\nNone\niSTAR-Edge\n6.x\nNone\niSTAR Ultra\n6.x\nNone\niSTAR Ultra SE\n6.x\nNone\n(Pro Mode and Ultra Mode)\nDMP XR500E\n2.x\n512 Zones and Encryption\nDMP XR500N\n2.x\n512 Zones\nC-CURE 9000 UL Addendum\n13\nEFTA01224560\n", "char_count": 891}, {"efta_number": "EFTA01224546", "page_number": 15, "text_content": "DMP XR100N\nPower Supply Backup Systems\n⚫ apS\n2.x\n142 Zones\nRM Series Readers:\n⚫ RM2L-4000-PI26, RM2-4000-PI26, RM1-4000, RM2-4000, RM2L-4000, RM1-IC,\nRM2-IC, RM2L-IC, RM1-MP, RM2-MP, RM3-MP, RM2L-MP, RM1-PH, RM2-PH,\nRM2L-PH, RM3-PH, RM1-PI, RM2-P1, RM2L-PI, RM1-W\nSWH Series Readers:\n• SWH-4000, SWH-4100, SWH-4130, SWH-2100, SWH-5100, SWH-5200, SWH-\n4200, SWH-3100\nAccessories\n• RM-4, RM-DCM2, RM-4E, RM-4T, RM-4TE\n• 1/8, R/8, 18-CSI\nThe following system components have not been tested to UL requirements.\n• Optional communication converter: AS002\n• Optional dual communication converter: AS003\n•\nSmart Card Readers: SCR series of readers.\n• Auxiliary relay module: ARM-1\nNOTES:\nAll other readers not manufactured by Software House. (However, these readers\nmay be UL Listed. Contact the manufacturer for details.\n• Only readers included in the UL Components section can be employed in a\nUL-compliant system.\n•\nAll interconnecting devices are to be UL Listed and, if applicable, powered only by\nUL Listed access control or burglar alarm power-limited power supplies capable of\n24 hours of standby power.\n⚫ See individual panel installation instructions for panel-specific compatible readers,\naccessories, and power supplies.\n•\nAn RM2L-4000 reader must be in each area/partition for signal acknowledgement.\n14\nC•CURE 9000 UL Addendum\nEFTA01224561\n", "char_count": 1347}, {"efta_number": "EFTA01224546", "page_number": 16, "text_content": "Installation Manuals\nTable 4 Installation Guide Reference Chart\nAccess Control Panel\napC/8X\nUM-247\niSTAR Pro\niSTAR eX\niSTAR Edge Quick Start (2 & 4-Rdr)\niSTAR Edge 1-Rdr Quick Start\nUM-293\nUM-248\nUM-298\nUM-274\niSTAR Ultra\nUM-266\niSTAR Ultra SE\nUM-311\nAuxillary Boards\nRM-4\nRM-DCM2\nRM-4T\nUM-064\nUM-215\nUM-302\nI/8\nUM-204\nI/8-CSI\nUM-218\nR/8\nUM-205\nReaders\nRM1\nUM-207\nRM2\nUM-207\nRM3\nUM-207\nRM-IC\nUM-208\nRM2L-4000\nRM2L-NH\nRM2-4000-PI26 & RM2L-4000-PI26\nUM-209\nUM-235\n8200-1179-01\nC-CURE 9000 UL Addendum\n15\nEFTA01224562\n", "char_count": 515}, {"efta_number": "EFTA01224546", "page_number": 17, "text_content": "Stratus Fault Tolerant Solution for C•CURE\nStratus Technologies' everRunⓇ fault tolerant redundancy solutions deliver a fault tolerant\nsolution that requires limited or zero downtime. Stratus Technologies' everRun Enterprise and\nExpress, and SplitSite provide a high availability, fault tolerant solution for C•CURE 9000\nsystems. Stratus everRun fault tolerant redundancy platforms offer additional reliability to\nC•CURE access control systems. While some redundancy platforms run on a recovery-based\nmodel in the event of failures, everRun platforms utilize a new preventative-based model which\nallows ability to continue to compute through failures. everRun Snapshots provide information\nrollback of the C•CURE database at a single point in time to assist with the recovery of data loss\nor system corruption.\neverRun Enterprise and Express\neverRun Enterprise and Express combining the physical resources of two standard Windows\nservers into a single, unified operating environment. This provides complete redundancy of all\nunderlying data and hardware. By keeping the operating environment in the single, unified\nsystem you are able to keep applications up and running in the event of a system or component\nfailure. everRun Enterprise provides a full, level-3 fault tolerant system with no restarts for\ncontinuous operation. everRun Express provides a component, level-2 fault tolerant system with\nfailover restart in seconds to minutes for minimal downtime. everRun is a fault tolerant solution\nthat supports symmetric multiprocessing and multi-core environments, allowing businesses to\nhave an affordable, continuous security solution during component system failures.\nServers that employ the everRun Enterprise and Express solution are required to be in the same\nroom of each other ideally less than 6 Feet.\neverRun SplitSite\neverRun SplitSite delivers fault tolerance between systems located in a campus type of\nenvironment. Utilizing a LAN, everRun SplitSite links geographically separated sys\n... [truncated, 2641 chars — for the full page use /api/corpus/document/EFTA01224546/17 or ?id=EFTA01224546&page=17]", "char_count": 2641}, {"efta_number": "EFTA01224546", "page_number": 18, "text_content": "everRun Diagram\nSMP-based Server\nSMP-based Server\nWorkload #1 App \"A\"\nComponent\nStorage\nAvailability Linka\nProduction Network\ngement Network\neverRun SplitSite Diagram\nQuorum Computer\nQuorum Site(s)\nStorage\nPrimary Site verfun Host\nvalability\nApp \"A\" Workload #1\nProduction Network\nManagement Network\nManagement\nConsole\nManager\nComponent\nManagement\nQuorum Computer\nMaster\nRun Host Remote Site\nNotes:\nOnly one Management Console needed\nQuorum computer required to be in third location (not primary or remote site)\nMultiple Production networks are supported\nStratus Technologies' everRun S/W running on Servers will protect and keep mission critical\ndata and applications available by mirroring information from one server to another over a local\narea network (LAN). Data is updated in real time. Should a server fail, the peer server will\nassume control of the system with an exact copy of the data and application.\nUL Listed Encrypted Line Security Configuration.\nC-CURE 9000 UL Addendum\n17\nEFTA01224564\n", "char_count": 1003}, {"efta_number": "EFTA01224546", "page_number": 19, "text_content": "Conceptual View of Network\nA conceptual view of the UL Listed Encrypted Line Security Configuration is shown in the\nfollowing diagram \"Conceptual View of Campus Network.\"\nThe head end LAN is isolated from the campus network by a firewall and an encrypting router\n(Cisco Router 891). Communication from the C•CURE 9000 server to the iSTAR Pro panel is\nthrough an encrypted VPN tunnel between the two encrypting routers (both Cisco Router 891).\nThe Cisco 891 routers have been validated as correctly implementing the Advanced Encryption\nStandard (AES 256-bit) algorithm, specified in the Federal Information Processing Standard\nPublication 197 (FIPS 197), Advanced Encryption Standard.\nCampus Network Design - Conceptual View\nHead End LAN\nincluding Servers\n& Workstations\nCisco Router\n891\nFirewall\nEncrypted Tunnel\nCisco Router\nCampus Network\niSTAR Pro\n891\nPanel\nEncryption Methods\nConceptual View of Campus Network\nC•CURE 9000 controllers use the following encryption methods:\n⚫ iSTAR Ultra SE in Pro Mode - AES 256-bit encryption, FIPS 197, when used with\napproved Software House routers.\niSTAR Ultra SE in Ultra Mode - AES 256-bit encryption, FIPS 197-listed, with custom\nkey management and digital certificates.\niSTAR Ultra - AES 256-bit encryption, FIPS 197-listed, with custom key management\nand digital certificates.\niSTAR Pro - AES 256-bit encryption, FIPS 197, when used with approved Software\nHouse routers.\niSTAR eX-AES 256-bit encryption, FIPS 197-listed with custom key management and\ndigital certificates.\n⚫ iSTAR Edge - AES 256-bit encryption, FIPS 197-listed, with custom key management\nand digital certificates.\n⚫ DMP XR500E - AES 128-bit encryption, with custom key management and digital\ncertificates.\n18\nC•CURE 9000 UL Addendum\nEFTA01224565\n", "char_count": 1759}, {"efta_number": "EFTA01224546", "page_number": 20, "text_content": "UL 1076 Line Security\nStandard line security will detect a compromise in the communication channel between the\ncentral receiving station and the protected area. Standard line security is default enabled and is\nverified by disconnecting the protected area from the receiving station and receiving notification\nof disconnection. Reconnect the communication line and verify communication has been\nrestored,\nEncrypted line security is detailed on page 18. In default encryption mode, the digital certificates\nare generated internally. Please refer to the appropriate hardware manual for any hardware\nconfiguration.\nUL Switching Protection Mode Requirements\nThere are two Arming Mode methods. The first method is no intrusion zone arming if connection\nto the host is lost. The second method is indication of acknowledgement from the central\nsupervising station of arming of intrusion zone.\nThe First Method:\nA control unit shall provide a visual and/or audible signal to indicate to the attendant at the\nprotected area that the closing signal has been received by the central supervising station.\nThe protection zone shall contain at least one RM2L-4000 reader, which will utilize keypad\ncommands.\nThe keypad command will activate a host based event which arms/disarms the protection zone.\nCreate a keypad command that will activate a controller based event. The controller event will\nthen activate a host based event. The host based event will arm the protected area.\nWith the RM2L, the acknowledgement on the LCD will indicate \"area secured\". If the\nmonitoring station has not received the signal, no message will be displayed.\nThe Second Method:\nConversely, the control unit shall provide a visual and/or audible signal to indicate to the\nattendant at the protected area that the closing signal has been received by the central supervising\nstation.\nWhen arming an intrusion zone, create a host based event that will activate an output that will\nnotify the arming personnel that the host received the ar\n... [truncated, 2257 chars — for the full page use /api/corpus/document/EFTA01224546/20 or ?id=EFTA01224546&page=20]", "char_count": 2257}, {"efta_number": "EFTA01224546", "page_number": 21, "text_content": "A representative LED would be part number 1091M5-12V by CML (Chicago Miniature\nLighting). It is 12V, 2W (0.1667A) rated. It has 390ohms internal. The LED can be connected\nto the output of the RM2L-4000, or the output of the iSTAR and UL listed supply capable of\npower, or if wet outputs on the iSTAR.\nFor specifics on creating host based events, refer to the CCURE 9000 guides.\nCisco 891 Router\nSecure Network Connectivity\nCisco 890 Series Routers deliver high performance with integrated security and threat defense.\nNetwork security has become a fundamental building block of any network, and Cisco routers\nplay an important role in embedding security at the customer's access edge. Cisco recognizes this\nrequirement, so Cisco 890 Series Routers are equipped with security hardware acceleration and\nCisco IOS Software (by default, a universal image with Advanced IP Services feature license).\nThis Cisco IOS Software feature set facilitates hardware-based IPsec encryption on the\nmotherboard and provides a robust array of security capabilities such as Cisco IOS Firewall,\ncontent filtering, IPS support, IPsec VPNS (DES, 3DES, and AES), SSL VPN, tunnel-less Group\nEncrypted Transport VPN, DMVPN, Easy VPN server and client support, Secure Shell (SSH)\nProtocol Version 2.0, and Simple Network Management Protocol (SNMP) in one solution set.\nCISCO\nCisco 891 Router\nCisco 800 Series\nNetwork Configuration\nThe \"UL Listed Encrypted Line Security Configuration\" drawing shows a sample wiring\ndiagram for the Cisco Router UL Test Configuration.\n⚫ The Cisco encryption device and iSTAR control panels must be installed in the same\nroom.\nThe Cisco 891 router must be powered by Cisco power supply [P/N 341-0231-02] in all\ninstallations.\n⚫ The power supply must be connected to an uninterruptible power supply (UPS) LISTED\nto UL 1076.\nNOTE: UL has not evaluated the wireless or POE capabilities of this router.\n20\n20\nC•CURE 9000 UL Addendum\nEFTA01224567\n", "char_count": 1947}, {"efta_number": "EFTA01224546", "page_number": 22, "text_content": "Cisco Router 891 UL Test Configuration and Setup\nCisco 891: S/N: FTX1405YBE6\nFELAN 0-7 All Devices on 40.40.40.x/24\nSubnet mask: 255.255.255.0\nGateway: 40.40.40.1\nWAN FES All Devices on 20.20.20.x/24\nSubnet mask: 255.255.255.0\nGateway: 20.20.20.1\nWAN GEO All Devices on 30.30.30.x/24\nSubnet mask: 255.255.255.0\nGateway:\nUsername: manager\nPassword: manager\nip default-gateway 20.20.20.2\n30.30.30.1\niproute 10.10.10.0 255.255.255.0 20.20.20.2\nip route 10.10.10.0 255.255.255.0 30.30.30.22\n20.20.20.2\nCisco 891: S/N: FTX1405YE32\nFELAN 0-7 All Devices on 10.10.10.x/24\nSubnet mask: 255.255.255.0\nGateway: 10.10.10.1\nWAN FES All Devices on 20.20.20.x/24\nSubnet mask: 255.255.255.0\nGateway: 20.20.20.2\nWAN GEO All Devices on 30.30.30.x/24\nSubnet mask: 255.255.255.0\nGateway: 30.30.30.2\nUsername: manager\nPassword: manager\nip default-gateway 20.20.20.1\nip route 40.40.40.0 255.255.255.0 20.20.20.1\nip route 40.40.40.0 255.255.255.0 30.30.30.12\nWAN GE\n20.20.20.1\nWAN GE\nor FES\nor\nor\nor FES\nCisco Router 891\n30.30.30.1\n30.30.30.2\nLAN FEO-7\nCisco Router 891\nLAN FEO-7\nPC-Dell GX620\nIP:40.40.40.32\nLogin: hcao\nPassword: psd\nC-CURE 9000 UL Addendum\niSTAR Pro\nIP: 10.10.10.2\nMAC\n0050F9 00708F\niSTAR ex\nIP: 10.10.10.3\nMAC\n0050F9 080432\niSTAR Edge\nIP: 10.10.10.4\nMAC\n0050F9 08049E\nRM2L\n-4000\nRM2L\n-4000\nRM2L\n-4000\nRM2L\n-4000\niSTAR Ultra\nIP: 10.10.10.5\nRM2L-4000\n21\nEFTA01224568\n", "char_count": 1363}, {"efta_number": "EFTA01224546", "page_number": 23, "text_content": "UL Notes\n⚫ FIPS 140-2 not evaluated by UL.\n•\nPCMCIA not evaluated by UL.\n•\nDHCP not evaluated by UL.\n• Tamper, power failure, low battery enabled for UL installations.\n⚫ Communication failure must be enabled for UL installations.\n•\nElevator output assignment not evaluated by UL.\n•\nElevator controls not evaluated by UL.\n•\napC, apC/L not evaluated by UL.\n•\nUnsupervised inputs not evaluated by UL.\n•\nMini star reader not evaluated by UL.\n•\nISC controllers not evaluated by UL.\n•\nSecondary communication ports not evaluated by UL.\n⚫ UL requires a maximum of 200 seconds supervision on the communication line between the ported\npremise and central station.\n⚫ Cluster tab not evaluated by UL.\n•\nSend state changed to the monitoring station must be selected.\n•\nRange 1-99, 10 is default, 99 must be selected for UL installations.\n•\nVideo support not evaluated by UL.\n⚫ Bi-directional interface for CCTV not evaluated by UL.\n•\nNet view not evaluated by UL.\n• Controller based Key management not evaluated by UL.\n•\nHost based key management not evaluated by UL.\n• Custom encryption not evaluated by UL.\n•\nDigital Certificates not evaluated by UL.\n•\nOSDP (Open Supervised Device Protocol) not evaluated by UL.\n22\nC•CURE 9000 UL Addendum\nEFTA01224569\n", "char_count": 1243}]}