{"efta_number": "EFTA01205397", "page_count": 2, "url": "https://epstein-data.com/EFTA01205397", "pdf_url": "https://epstein-data.com/pdf/EFTA01205397.pdf", "pages": [{"efta_number": "EFTA01205397", "page_number": 0, "text_content": "clarity\nCUSTOM AUDIO VIDEO\nJuly 30, 2015\nLUTRON LIGHTING SYSTEM ESTIMATE 2\nCentralized and Decentralized Dimming devices\nMr. Richard Kahn\nHBRK Associates Inc.\nRe: 9 East 71st Street\nNew York NY\nEquipment\nLabor\n575 Lexington Avenue, 4th Floor\nNew York, NY 10022\nNY Sales Tax\nTotal\n$134,762\n111,100\nn/a\n$245,862\nBelow is a list of components required for a system conversion from a Lutron analog DP panel based system to a\ndigitally controlled Homeworks QS system. Centralized keypad controlled dimming is scheduled for all common\nareas as replacements to the analog keypads. Selective decentralized \"smart dimmers\" are included for key\nareas such as office and security room.\n7\n82143NIN\nQty Brand\nLutron\nModel\nITEMIZED EQUIPMENT AND LABOR\nDescription\nLutron\nHQP6-120\nLutron\nLutron\nLutron\nHQ-LV21-120\nHWA-8P-15\nHWI-PNL-5\nLutron\n40\nLutron\nHWI-MI-120\nHW-RPM-4A\nLutron\nQSPS-DH-1-60\n1\nLutron\nQSGR-6P\n1\nLutron\nQSE-IO\n4\nLutron\nQSW-LB\n63\nLutron\nHQWA-XBRL\n12\nLutron\nHQR-REP-120 RF system repeaters\nPHPM-PA-120\nQS series Homeworks microprocessor with RF link\n21\" Enclosure for processor and power supply\n59\" Enclosure, Feed through AFCI breaker panel holds 8 RPM\n32\" Enclosure, Feed through panel holds 5 RPM (emergency)\nModule interface for PNL enclosures\nPowered module with 4 centralized dimming zones\nDin rail power supplies for processors and keypads\nQS Graphic Eye 6 load dimming module\nQS contact closure board for relay\nWire landing board and terminal blocks\nWired seeTouch x Button Unit Keypad & Engraving\nPhase Adaptive Power Module\n41\nLutron\nST-xx\nCustom metal plates\n18\nLutron\nMiscellaneous supplies: hardware, mounting supplies,\nHQRD-6NA-WH\nRF Maestro-Style 600W Auto sensing Dimmer (quantity tbd)\nLutron Equipment Total\n134,762\nINSTALLATION\n*Replacement of electrical panels using existing feeder\n*Replacement of electrical interface modules where required (allotment)\nWall framing for new PNL panels\nSystem discovery and engineering including full wire ID and termination\nInstallation and programming of selected \"smart\" switches\nInstallation and programming of all keypads including full engraving schedules\nSub Total\nCapitol improvement form required\nLutron QS Estimate 1\n1792 West 11th Street Brooklyn NY 11223 Tel\nwww.claritycustom.com\n39,800\n9,500\n13,800\n13,500\n17,250\n17,250\n245,862\nn/a\n$245,862\nEFTA01205397\n", "char_count": 2319}, {"efta_number": "EFTA01205397", "page_number": 1, "text_content": "clarity\nCUSTOM AUDIO VIDEOI\nRe: 9 East 71st Street Lutron system replacement, 7/30/15, page 2 of 2\nOPTIONAL EQUIPMENT DESCRIPTION\nThe addition of direct replacement \"smart dimmers\" will allow for all rooms to be included in the Lutron lighting\ncontrol system. The options are installing a \"smart dimmer\" in locations where standard dimmers are located or\nadding pushbutton keypad control in addition to the smart feature. This could be very useful in locations where\nlighting control is desired and only dimmers are available.\nSCOPE OF WORK\nThis estimate is to replace an existing 25 year old Lutron DP analog lighting control system with a digitally\ncontrolled Lutron Homeworks QS system. There are currently three customized DP panels operating both\nnormal and emergency lighting loads. Replacement panels will be segmented to include normal and emergency\nlighting loads as well. Panels will be removed and the locations reframed to accommodate the new panels.\nPlastering and painting will be by others.\nAll lighting keypads will be removed and wiring will be tested and identified for proper communication. Wiring\nbetween Lutron panels is essential and every effort will be made to verify that wiring exists or can be easily\nadded. Additional equipment will be required if panel to panel wiring does not exist or cannot be installed. The\nnew style keypads are sized as single gang devices. Included are additional keypads in areas where double\ngang switching occurs. It is strongly recommended that this condition be discussed as soon as possible as\ncustom cover plates, especially metal, can be costly and have very long lead times.\nASSUMPTIONS & CONDITIONS:\n- Lighting loads are as listed in Lutron Job document 012-8144-R7. This document is approximately 25 years\nold and changes to the load schedule may affect the estimate.\n- All wiring to low-voltage keypads will pass a full continuity test.\nLow voltage digital keypads are able to transmit and receive data over existing unshielded wiring.\n-If unshielded wire cannot transmit data conversion to wireless keypads will be required and accepted should\nexisting wiring fail as a digital communication propagation method. (approximately $5000 additional hardware\ncost)\n- Existing communication wiring between Lutron electrical equipment throughout the residence is required for\nsingle Lutron processor operation and for whole home control to be effective. Additional processors will be\nrequired. ($4000-$7000) pending existing wire conditions.\n- Existing Keypad cover plates are oversized. Custom cover plates will be required in some locations. Pricing\nThe Keypads in this estimate include a screw-less plastic cover plate. Metal screw-less cover plates are\navailable from Lutron as a custom order product.\nProject will require a minimum of 3 weeks for substantial completion of the system conversion.\nAdditional programming and engraving time will be required pending aforementioned assumptions and\nconditions.\nLight loads connected to the Lutron panels will not be functional for the majority of the upgrade.\nUnknown conditions may cause cost overages and require additional time to completion.\n1792 West 11th Street Brooklyn NY 11223 Tel\nwww.claritycustom.com\nEFTA01205398\n", "char_count": 3233}]}