{"efta_number": "EFTA01201855", "page_count": 3, "url": "https://epstein-data.com/EFTA01201855", "pdf_url": "https://epstein-data.com/pdf/EFTA01201855.pdf", "pages": [{"efta_number": "EFTA01201855", "page_number": 0, "text_content": "27-66\nFOR TRAINING PURPOSES ONLY\nEFTA01201855\nESS\nDC\nBUS\nFLAP\nEMER\nCONT\nMANUAL\nFLAP CONT\nFLAP/STAB\nPOS\nPEDESTAL\nSWITCHES\nUP\nFOLLOW UP\nSWITCHES\nFLAP 10°\n20°\nDN\nNORM\nEMER FLAP\nSWITCH\nFLAP\nCONTROL\nEMER FLAP\nHANDLE\nVALVE\nEXT\nRET\nASYMMETRY\nSWITCHES⭑\n1\n¡FLAP INFORMATION\nFLAP\nCONTROL\nRELAY\nSTAB POSITION\nTRANSMITTER\n00000000\nFLAP POSITION\nTRANSMITTER\nSTAB/FLAP\nINDICATOR\nFLAP SHUTOFF VALVE\n(DEENERGIZED-CLOSED)\nAUXILIARY\nPRESSURE\nCOMBINED (OR UTILITY)\nPRESSURE\nSTABILIZER INFORMATION\nLEGEND\nMECHANICAL\n* BREAK CIRCUIT IF ACTUAL FLAP\nLINEAR TRAVEL EXCEEDS APPROX\n1/4 INCH. ONE FROM THE OTHER\nFigure 27-37. Flap Control System Block Diagram\nFlightSafety\nInternational\n☑GULFSTREAM GIV/G300/G400 MAINTENANCE TRAINING MANUAL\n", "char_count": 714}, {"efta_number": "EFTA01201855", "page_number": 1, "text_content": "FlightSafety\nInternational\nGULFSTREAM GIV/G300/G400 MAINTENANCE TRAINING MANUAL\n(\nCentral Gearbox\nThe central gearbox is mounted on the forward\nupper end of the torque box in the main wheel\nwell. The gearbox has an input shaft and four\noutput shafts. The input shaft is driven by the\nhydraulic motor. The hydraulic motor is a\nfixed displacement motor operating at 6,000\nrpm. This speed is reduced in the central gear-\nbox at a ratio of 8.22 to 1. Torque is transmitted\nat a speed of 730 rpm to the spanwise torque\nshafts to drive the flaps and to drive the hor-\nizontal stabilizer. The fourth output is to the\nflap followup switch assembly and the posi-\ntion transmitter.\nFlap Control Handle\nThe flap control handle is located on the right\nside of the center pedestal. It moves vertically\ninto four detented positions: UP (0°), 10°,\nTAKEOFF/APPROACH (20°) and DOWN\n(39°).\nThe emergency flap control handle is located\non the copilot's side console. It is mechanically\nlinked to the flap selector valve and is used as\na manual override in the event of an electri-\ncal malfunction in the flap control valve. The\nhandle moves vertically through three de-\ntented positions: UP, DOWN, and NEUTRAL.\nTo operate the flaps with the emergency han-\ndle, move it in the desired direction and when\nthe flaps reach the desired position return the\nhandle to neutral.\nFlap Selector Valve\nThe flap selector valve is located in the nose\nwheel well, right side. It is a dual solenoid-op-\nerated valve. Solenoid \"A\" is energized for\nflaps up and solenoid \"B\" is energized for\nflaps down. The two positions provide re-\nversing hydraulic flow to the hydraulic motor\nfor flap operation. The automatic stopping\nfeature of the flaps is controlled by the flap fol-\nlowup switch assembly. When the flaps reach\nthe desired position, one of the followup\nswitches opens the electrical circuit to deen-\nergize the respective solenoid valve. This\nresults in the hydraulic motor stopping and the\nflaps being held in the desired position. If the\nselector valve solenoids fail, the emergency\nhandle can be used to operate the valve.\nFlap Shutoff Valve\nThe flap shutoff valve is located in the nose\nwheel well forward of the selector valve. It is\na single solenoid valve that must be energized\nopen. When energized, it will allow hydraulic\nfluid to the flap selector valve. It is energized\nwhenever the flap control handle is moved. If\nthe flap control circuit breaker should blow due\nto an electrical failure in the normal flap con-\ntrol circuit, the valve can be energized through\na separate circuit and the emergency flap con-\ntrol handle can be used to move the flaps.\nShould a flap asymmetry occur during normal\nor emergency operation, the shutoff valve will\nbe de-energized to prevent flap operation.\nNOTES\nFOR TRAINING PURPOSES ONLY\n27-65\nEFTA01201856\n", "char_count": 2822}, {"efta_number": "EFTA01201855", "page_number": 2, "text_content": ")\nFlightSafety\nInternational\nGULFSTREAM GIV/G300/G400 MAINTENANCE TRAINING MANUAL\nELECTRICAL OPERATION\nPower for the flap control system is supplied\nby the FLAP CONT circuit breaker powered\nfrom the ESS DC bus. Additionally, the MAN-\nUAL FLAP CONT circuit breaker is powered\nthrough an integral switch in the FLAP CONT\ncircuit breaker whenever it opens.\nThe control system consists of four switches\nactuated by the flap control handle. Addi-\ntional control comes from the flap followup\nswitch assembly. The assembly contains six\nflap position switches and five warning\nswitches as well as control switches for other\naircraft systems. These switches open and\nclose as the flaps cycle through their range of\n0 to 39°. As the flaps reach a selected position,\nthe drive cam opens the particular switch,\nbreaking the circuit to the flap selector valve\nand halting flap movement. Of the six flap\nposition switches, three control retraction and\nthree control extension.\nUP (S1) Retract\n10° UP (S3)-Retract\n10° Down (S4)-Extend\n20° UP (S5)-Retract\n20° DOWN (S6)-Extend\nDOWN (S2)-Extend\nThe remaining switches in the assembly also\nopen and close through the drive cam action\nin correspondence to flap position to allow cer-\ntain circuits to be completed.\nLanding Gear Warning Horn (S7)-Flaps equal\nto or greater than 22°\nTakeoff Alarm (S8)-Flaps full up or down\nHydraulic Control (S9), not used\nSpeedbrake/Flap Alarm (S10)-Flaps any po-\nsition except up\nFlap/Stab Warning (S11)-Flaps full up, stab\nnot at 1±1/4°\nAFGCS (S12) Flaps any position except up,\nnot used\nNOTES\nFOR TRAINING PURPOSES ONLY\n27-67\nEFTA01201857\n", "char_count": 1606}]}