{"efta_number": "EFTA01097435", "page_count": 5, "url": "https://epstein-data.com/EFTA01097435", "pdf_url": "https://epstein-data.com/pdf/EFTA01097435.pdf", "pages": [{"efta_number": "EFTA01097435", "page_number": 0, "text_content": "GENERAL\nPOWER\nDiesel Generators 10-3200 Kw | Alternators 5-3500 Kva | Transfer Switches | Fuel Tanks | Trailers | Engine Parts | Alternator Parts\nSDMO | KOHLER | BROADCROWN | HIPOWER | JOHN DEERE | CUMMINS | PERKINS | MITSUBISHI | VOLVO | STAMFORD | LEROY SOMER\nGP J100UC3 Engine JOHN DEERE, 4045HFS83, EPA/CARB Tier 3\n100 KW JOHN DEERE GENERATOR\n100 KW/ 125 KVA DIESEL GENERATOR SET, FULLY PACKAGED:\n.\n•\n.\nJOHN DEERE Heavy duty diesel engine, 4 stroke, 1800rpm, Turbo, EPA\nLEROY SOMER brushless alternator. IP23 protection, Insulation class H\nSCHNEIDER, Main line circuit breaker, wired, maximum output rated\nEPA Tier 3 compliant engine per U.S. Environmental Protection Agency\nDigital auto-start control panel. CE and UL compliant\nIncorporated metallic fuel tank for day use\nAuto Start control feature included for interoperation with ATS/AMF\n12V charging alternator and 12V DC electric starter motor\n12V charged DC starting battery with electrolyte and cables\nDry type air filter, fuel filter and oil filter elements installed\nMechanically welded chassis with vibration isolators\nEach unit prototype and individually factory load bank tested\nThe generator accepts 100% rated load in one step as per NFPA110\nand meets ISO8528-5 class G-3 for transient response\nCompliant with ISO3046, ISO8528, BS4999, BS5514, BS5000PT99,\nAS1359, IEC34, UTE5100, VDE0530 and ISO9001:2000\nAVAILABLE ACCESSORIES AND OPTIONS:\n•\n•\nSteel or Aluminum weather proof, sound attenuated enclosures\nUL142 listed, double wall fuel tanks from 50 to 10,000 Gal\nUL1008 listed, automatic transfer switches from 50 to 3000 Amp\ncompliant heavy duty road trailers from 3000 to 30000 Lbs\nAutomatic battery chargers, Engine preheaters, Remote annunciators\nand many more\nAlternator LEROY SOMER, LSA44.3S5\nPower ESP\nVoltage\nkWe/kVA\nPower PRP\nkWe/kVA\nStandby Amps\nDimensions - Open\nWeight - Open\n480/277\n100/125\n91/114\n150\n460/265\n100/125\n91/114\n157\n440/254\n100/125\n91/114\n164\n240/139\n100/125\n91/114\n301\nLength: 1950mm [77in]\nWidth: 1084mm [43in]\nHeight: 1350mm [53in]\n1187kg [2617lbs] Net\n1440kg [3175lbs] Gross\n230/133\n100/125\n91/114\n314\n220/127\n100/125\n91/114\n328\n208/120\n100/125\n91/144\n347\nPOWER DEFINITION\nPRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO\n8528-1.\nESP: The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-\n1. Overload is not allowed.\nTERM OF USE\nStandard reference conditions ESP/PRP 25 C°/25 C° Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.\nWEATHER / SOUND PROOF ENCLOSURES\nModel\ndB(A)@3ft dB(A)@23ft\nM129\n78\n68\nDimensions - Enclosed\nLength: 2554mm [101in]\nWidth: 1150mm [45in]\nHeight: 1680mm [66in]\nWeight - Enclosed\n1597kg [3521lbs]\n1850kg [4079lbs]\nTank\n190 L\n50 Gal\nGENERAL POWER LIMITED, INC\n1350 NW 78 Avenue / Miami, Florida 33126\nEFTA01097435\n", "char_count": 2911}, {"efta_number": "EFTA01097435", "page_number": 1, "text_content": "GENERAL\nPOWER\nDiesel Generators 10-3200 Kw | Alternators 5-3500 Kva | Transfer Switches | Fuel Tanks | Trailers | Engine Parts | Alternator Parts\nSDMO | KOHLER | BROADCROWN | HIPOWER | JOHN DEERE | CUMMINS | PERKINS | MITSUBISHI | VOLVO | STAMFORD | LEROY SOMER\nENGINE SPECIFICATIONS\nEngine model\nCylinders-arrangement\nDisplacement (C.I.)\nJOHN DEERE 4045HFS83,\n4-strokes, TURBOCHARGED, AIR/AIR, 4 Cylinders,\nU.S. EPA/CARB TIER 3\n4-L\n4.48\nBore (mm) X Stroke (mm)\nCompression ratio\n106 X 127\n19:1\nDATA\nSpeed (RPM)\n1800\nPistons speed (m/s)\n7.62\nGENERAL DATA\nMaximum stand-by power at rated RPM (KW)\nFrequency regulation (%)\n118\n+/-0.5%\nEXHAUST SYSTEM\nBMEP (bar)\nGovernor type\nExhaust gas temperature (°C)\nExhaust gas flow (L/s)\nMax. exhaust back pressure (mm CE)\nFuel consumption 110% load\n31.1 L/hr [8.2 gal/hr]\n15.9\nELECTRONIC\n580\n380\n750\nFUEL SYSTEM\nOIL\nTHERMAL BALANCE\nAIR INTAKE\nEMISSIONS\nFuel consumption 100% load\n28.5 L/hr [7.6 gal/hr]\nFuel consumption 75% load\n24.8 L/hr [6.6 gal/hr]\nFuel consumption 50% load\nMaximum fuel pump flow\nOil capacity (L)\nMin. oil pressure (bar)\nMax. oil pressure (bar)\nOil consumption 100% load (L/h)\nCarter oil capacity (L)\nHeat rejection to exhaust (kW)\nRadiated heat to ambiant (kW)\nHaet rejection to coolant (kW)\nAIR INTAKE_entree_max%\n17.7 L/hr [4.7 gal/hr]\n74.7 L/hr [19.7 gal/hr]\n13\n1.05\n3\n0.08\n12\n111.15\n14.39\n62.3+19.8\n375\nIntake air flow (L/s)\n136\nEmissions PM (g/kWh)\n0.25\nEmission CO (g/kW.h)\n1.47\nEmissions HCNOx (g/kWh)\n3.43\nEmission HC (g/kW.h)\n0.14\nGENERAL POWER LIMITED, INC\n1350 NW 78 Avenue / Miami, Florida 33126\nEFTA01097436\n", "char_count": 1581}, {"efta_number": "EFTA01097435", "page_number": 2, "text_content": "GENERAL\nPOWER\nDATA\nGENERAL DATA\nOTHER\nDATA\nDiesel Generators 10-3200 Kw | Alternators 5-3500 Kva | Transfer Switches | Fuel Tanks | Trailers | Engine Parts | Alternator Parts\nSDMO | KOHLER | BROADCROWN | HIPOWER | JOHN DEERE | CUMMINS | PERKINS | MITSUBISHI | VOLVO | STAMFORD | LEROY SOMER\nALTERNATOR SPECIFICATIONS\nAlternator brand\nAlternator\nLEROY SOMER\nLSA44.3S5\n3\nNumber of phase\nPower factor (Cos Phi)\nAltitude (m)\nOverspeed (rpm)\nNumber of pole\nExcitation system / Short Circuit reactance capability\nInsulation class / Temperature class\nAutomatic Voltage Regulator\nTotal harmonics TGH/THC\nWave form : NEMA=TIF-TGH/THC\nWave form: CEI=FHT-TGH/THC\nNumber of bearing\nCoupling\nVoltage regulation 0 to 100%\n0.8\n<1000\n2250\nAuxiliary Excitation / 300% for 10 seconds\nH/H\nAdvanced, R438\n<2\n<50\n<2\n1\nDIRECT\n+/-0.5%\n500\n131\n144\nEfficiencies 4/4 load (%)\nAir flow (cfm)\n91\n0.44\n0.33\n377\nRecovery time (Delta U = 20% transitoire) (ms)\nContinuous Nominal Rating 40°C (KVA)\nStandby Rating 27°C (KVA)\nShort circuit ratio (Kcc)\nDirect axis synchro reactance unsaturated (Xd) (%)\nQuadra axis synchro reactance unsaturated (Xq) (%)\nOpen circuit time constant (T'do) (ms)\n226\n2555\n(%)\n15\n(ms)\n100\n9\n10\n10.8\nDirect axis transient reactance saturated\nShort circuit transient time constant\nDirect axis subtransient reactance saturated (X\"d) (%)\nSubtransient time constant (T\"d) (ms)\nQuadra axis subtransient reactance saturated (X\"q) (%)\nZero sequence reactance unsaturated (Xo) (%)\nNegative sequence reactance saturated (X2) (%)\nArmature time constant (Ta) (ms)\nNo load excitation current (io) (ms)\n0.9\n9.9\n15\n0.5\nFull load excitation current (ic) (A)\n2.1\nFull load excitation voltage (uc) (A)\nRecovery time (Delta U = 20% transitoire) (ms)\nMotor start (Delta U = 20% perm. or 50% trans.) (ms)\nTransient dip (4/4 charge) - PF: 0,8 AR (%)\nNo load losses (kW)\nHeat rejection (kW)\n38\n500\n238\n17.8\n2.72\n10.25\nLEROY\nSOMER\nGENERAL POWER LIMITED, INC\n1350 NW 78 Avenue / Miami, Florida 33126\nEFTA01097437\n", "char_count": 1983}, {"efta_number": "EFTA01097435", "page_number": 3, "text_content": "GENERAL\nPOWER\nStandard\nOption\nDiesel Generators 10-3200 Kw | Alternators 5-3500 Kva | Transfer Switches | Fuel Tanks | Trailers | Engine Parts | Alternator Parts\nSDMO | KOHLER | BROADCROWN | HIPOWER | JOHN DEERE | CUMMINS | PERKINS | MITSUBISHI | VOLVO | STAMFORD | LEROY SOMER\nCONTROL PANELS\nMICS\nNEXYS\nTALYS\nACCESSORIES AND OPTIONS\nNEXYS\nSpecifications: Frequency meter, Ammeter, Voltmeter\nAlarms and faults: Oil pressure, water temperature,\nOvercrank, Overspeed (>60 kVA), Min/max alternator, Low\nfuel level, Emergency stop\nEngine parameters: Hours counter, Engine speed, Battery\nvoltage, Fuel level, Alr preheating\nTELYS2\nSpecifications: Frequency meter, Ammeter, Voltmeter\nAlarms and faults: Oil pressure, water temperature, No start-\nup, Overspeed, Min/max alternator, Min/max battery voltage,\nLow fuel level, Emergency stop\nEngine parameters: Hours counter, Oil pressure, Water\ntemperature, Engine speed, Battery voltage, Fuel level\nRemote monitoring and control\nOption\nASCO\nEMERSON\nNetwork Power\nAutomatic Transfer Switches, UL1008 listed: 100 to 4000 AMPS\nWith a Series 300 transfer switch, you get a product backed by\nASCO Power Technologies, the industry leader\n•True double-throw operation: single solenoid design is inherently\ninterlocked & prevents contacts from stopping between sources\n•Easy-to-read flush-mounted control and display panel provides\nLED indicators for switch position and source availability\n•Standard engine exerciser for weekly automatic testing with or\nwithout load\n⚫UL 1008 listed for Transfer Equipment and CSA C22.2 listed\n⚫NFPA 110 for Emergency & Standby Power & the National\nElectrical (NEC) Articles 700, 701 and 702\nOption\nUL\nLISTED\nFuel Tanks, UL142 listed: 50 to 5000 GAL\n⚫UL listed. Secondary containment tank meeting UL 142 tank\nrequirements\n⚫NFPA compliant. Designed to comply with the installation\nstandards of NFPA 30 and NFPA 37\n•Emergency pressure relief vents. Meets UL requirements; ensures\nadequate venting of inner and outer tank under extreme pressure\nand/or emergency conditions\n⚫Electrical stub-up area with removable end channel\nNormal vent⚫ Inner tank emergency vent sized to UL 142 specs\n•Direct reading mechanical fuel gauge • Fuel in basin switch\n•Satin black paint finish\nGENERAL POWER LIMITED, INC\n1350 NW 78 Avenue / Miami, Florida 33126\nEFTA01097438\n", "char_count": 2318}, {"efta_number": "EFTA01097435", "page_number": 4, "text_content": "GENERAL\nPOWER\nDiesel Generators 10-3200 Kw | Alternators 5-3500 Kva | Transfer Switches | Fuel Tanks | Trailers | Engine Parts | Alternator Parts\nSDMO | KOHLER | BROADCROWN | HIPOWER | JOHN DEERE | CUMMINS | PERKINS | MITSUBISHI | VOLVO | STAMFORD | LEROY SOMER\nM129\nSTANDARD FEATURES\nWeatherproof / Super Silent\nEnclosure\n12 gauge electro-zinc powder coated steel for maximum corrosion resistance (Phosphatizing degreasing, Non-chromic\npassivation, Osmosis purified rinsing and High durability polyester resin thermosetting powder paint)\n29dB(A) Internal-mounted critical silencer and flexible exhaust connector offering maximum component life and\noperator safety\n■Fade-, scratch-, and corrosion-resistant. Automotive-grade textured finish resulting in advanced corrosion and\nabrasion protection as well as enhanced edge coverage and color retention\nUp to 51mm (2in) Acoustic insulation with hydrocarbon sealing film that meets FMVSS 302 flammability classification\nand repels moisture absorption\nInterchangeable modular panel construction. Allows complete serviceability or replacement without compromising\nenclosure design\nService access. Multi-personnel doors for easy access to generator set controller, breaker and service points\nExternally mounted emergency stop button, Single point lifting hook and Tamper proof \"securit\" viewing control window\nCooling air discharge. Weather protective design featuring a vertical air discharge outlet grille. Redirects cooling air up\nand above enclosure to reduce ambient noise\nCooling/combustion air intake with a horizontal air inlet. Sized for maximum cooling airflow\nHeavy duty Polyamide plastic hinges, Dichromate galvanized bolting and Stainless steel rivets for lifetime longevity\nMeets and exceeds NFX41002 Salt spray test, NFT30049 UV Performance test, NFT30038 Paint adhesion test and\n2000/14EC Low sound directives\nwww.genpowerusa.com\nGENERAL\nPOWER\n0\nSound level\nModel\ndB(A)@3ft\ndB(A)@23ft\nLWA\nDimensions\n(in)\nWeight\nTank\n(lbs)\n(Gal)\nGP 100UC3\n78\n68\nN/A\n101 x 45 x 66\n3521\n50\nGENERAL POWER LIMITED, INC\n1350 NW 78 Avenue / Miami, Florida 33126\nEFTA01097439\n", "char_count": 2112}]}