{"efta_number": "EFTA01092129", "page_count": 1, "url": "https://epstein-data.com/EFTA01092129", "pdf_url": "https://epstein-data.com/pdf/EFTA01092129.pdf", "pages": [{"efta_number": "EFTA01092129", "page_number": 0, "text_content": "Commercial & Industrial HVAC Systems Complete Service Contracts 24 Hour Emergency Service\n43-15 36th Street Long Island City New York 11101\na.d.winston\nservice, inc.\nDear Mr. Barnett,\nwww.adwinstonservice.com\n04.02.13\nIn receipt of your request to cancel the multi stack chiller, we are currently waiting to hear from the\nfactory, to see if any charges will be incurred from cancellation.\nHowever, let me point out the following benefits for proceeding with this project:\nThe existing multi stack chiller consists of 4 compressors, which operates on demand to maintain\ndesired chilled water temperature. These compressors are controlled by a central chilled water\ncontroller; under normal conditions the chiller will operate 1-3 compressors. As outdoor temperature\nincreases, during hot summer weather, the fourth compressor will be used at times. Under extreme\nconditions temperatures from 95 degrees and above, the 40 ton carrier must be started, through the\nBMS system. This 40 ton chiller is approximately 25 years old, and has very poor efficiency rating-\napproximately 2 KW per ton or higher. By removing this inefficient chiller, and adding a new 30 ton\nmulti stack module, to the existing multi stack, you will increase the efficiency rating to 1.1 KW per ton.\nMore importantly, you will now have 6 compressors fully integrated into the multi stack chilled water\ncontrol system. This will give you complete and automatic redundancy. Also, if there are any\ncompressor failures in any module, the controller will automatically bring on additional compressors to\ncompensate for it. There would be no need for the BMS system to be involved, to open any valves and\nstart the chiller.\nI have reviewed this project with one of our design engineers, who were involved when we installed the\noriginal multi stacks. He believes that this is one of the better designs, he has ever seen in a residence. If\nthere are any issues in the house in specific areas, this should be treated separately, as there are\ndifferent air handlers, for different areas. Chiller systems are the most reliable and have the lowest\nfailure rate, whereas DX systems have many more components, controls, and compressors, along with a\ngreater rate of failure. As you know, we installed the original equipment in this residence; therefore we\nare extremely familiar with it.\nI strongly recommend you reconsider the cancellation of the chiller. If you have any concerns and\nor/problems, please feel free to discuss them with me.\nVery truly yours\nMichael A. Paladino\nVice President\nEFTA01092129\n", "char_count": 2561}]}