{"efta_number": "EFTA01075445", "page_count": 14, "url": "https://epstein-data.com/EFTA01075445", "pdf_url": "https://epstein-data.com/pdf/EFTA01075445.pdf", "pages": [{"efta_number": "EFTA01075445", "page_number": 0, "text_content": "PureLogic\nCLEAN ENERGY SYSTEMS\nProposal for Solar PV\nPrepared By:\n9/15/12\nBrannon Bloom\nPure Logic Clean Energy Systems\nPrepared For:\nJeffrey Epstein, Mechanical Building\nLittle Saint James Island\nLittle Saint James, USVI 00802\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075445\n", "char_count": 326}, {"efta_number": "EFTA01075445", "page_number": 1, "text_content": "Introduction\nThank you for allowing Pure Logic Clean Energy Systems to prepare this proposal for you. In the USVI electric\nrates are 4 times higher than the average continental rate and they fluctuate unpredictably. Solar PV has become a\nvery wise investment, partly due to tax credits, rebates, Feed-In-Tarrifs and accelerated depreciation which have\ncontributed to the rapid expansion of solar PV throughout the world. As a result, this very reliable 57-year old\ntechnology is being implemented on a massive scale as the world transitions to clean, sustainable energy systems.\nPure Logic is a licensed, insured, full service solar integrator. Our team will be responsible for:\n•\nAssistance in funding procurement\nDesign and Schematics\nStructural and Electrical Engineering\nPermitting\nRebate paperwork management\nFull project management\nInstallation\nElectrical Interconnection\nSystem Commissioning\nBOARD\n•\n•\nInspection Coordination\nMaintenance training\nSafety training\nWarranty\nNORTH AMERICAN\nProposed System:\nCERTIFIED\nSolar PV\nInstaller\nCERTIFIED\nCOSEIA\nColorado Solar Energy Industries Association\nColorado\nRenewable\nEnergy\nSociety\nSummary\nSystem Size\nCost\nAnnual Production\n120.8\n$609,721\n164,929\nkW DC\nkWh\nLocation\nRoof and Ground\nFirst Year\nTotal for 25 Years\nAnnual Production\n$92,360\n$3,201,208\nPay Back Period\n-4.5 Years\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075446\n", "char_count": 1429}, {"efta_number": "EFTA01075445", "page_number": 2, "text_content": "System Details:\nSolar PV System:\n• System will be Grid-Tied\n• Siliken 250 Watt modules on existing roof and ground\n• SMA Sunny Boy inverters (Qty., size and model to be determined at system design for optimum power output and\noverall performance)\n• S-Flex Aluminum/SS attachment hardware\nMounting plan:\nSystem to be mounted to existing roof and ground using S-Flex mounting system.\nIncludes all required AC hardware/devices to complete interconnection. (Pure Logic agrees to comply with all NEC\nand local building and electric codes.)\n• Remote system monitoring is included.\nSchedule: TBD\nOptions:\n1. Sunny SensorBox Weather station for advanced monitoring\n2. Back up option: Sunny Island\n3. Colored modules, ie; green to blend in with the enviroment\nEquipment Details:\nQuantity\nТуре\nMake\nModel\n483\nModules\nSiliken\n250\n17\nInverters\nSMA\nSB7000US\nn/a\nRacking System\nS-Flex\nRoof and Ground\n1\nMonitoring System\nSMA\nSunny Web Box\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075447\n", "char_count": 1023}, {"efta_number": "EFTA01075445", "page_number": 3, "text_content": "Benefits of switching to Solar Energy\nEnvironmental Benefits\nInstalling solar will help you reach your personal or corporate environmental objectives, reduce carbon dioxide\nemissions and other air pollutants, and help prevent climate change and a host of other environmental and\npublic health threats caused by fossil fuel energy.\nEnergy Savings\nA solar system on your building or property means you can both use the PV electricity and sell it to your utility\nfor credit to lower your utility bills. When the system generates more electricity than needed, your electricity\nmeter will run backward. If you need more electricity than the system generates, you use electricity from your\nutility as usual. Called \"net-metering,\" it reduces an electricity bill to the difference between how much a solar\nsystem produces and how much electricity is used.\nPrice Stability\nElectricity rates in the USVI increase as fuel prices increase, but the cost of sunlight never changes-it's always\nfree. When electricity from WAPA becomes more expensive, your solar system saves you more money and\npays for itself even faster.\nReliability\nFacilities that operate sensitive technology or need backup power for added reliability in case of brownout or\ngrid failure find solar-battery systems an attractive alternative to diesel generators, which pollute and can be\nexpensive to maintain. With solar you can truly be independent of WAPA and enjoy 100% uptime, even when\nthe grid goes down. During grid failure, our backup systems will switch automatically from Grid-Tied to Off-Grid\nwithin milliseconds.\nBrand Enhancement\nAfter installing a solar system, a business may qualify as a Certified Green Business, thus improving the\ncompany's profile, marketing potential, and product distinction. Green businesses attract a growing number of\nconsumers who are looking for businesses committed to environmental stewardship. Certified Green\nBusinesses also report that their environmental initiatives increase employee satisfac\n... [truncated, 2797 chars — for the full page use /api/corpus/document/EFTA01075445/3 or ?id=EFTA01075445&page=3]", "char_count": 2797}, {"efta_number": "EFTA01075445", "page_number": 4, "text_content": "System Cost\nProposal and Cost Analysis\nSystem Cost\n$609,721\n$5.05\nPer watt\nOther Discount\n$0.00\n$0.00\nPer watt\nContract Cost\n$609,721\n$5.05\nPer watt\n*WISE Rebate\n$0.00\n$0.00\nPer watt\n*VIEO Rebate\n$0.00\n$0.00\nPer watt\n*USDA Grant\n$0.00\n$0.00\nPer watt\n**Federal Tax Credit (30%)\n0\n0\nPer watt\nNet System Cost\n$609,721\n$5.05\nPer watt\nLevelized Cost per kWh\n$0.1607\nReturn on Investment\n17.35%\n*Rebates subject to availability **Consult your CPA on exact Tax Benefits.\nKilowatt Hours per Year\n70,000\n52,500\n35,000\n17,500\n% OFFSET\n19.91%\n0\nJan\nFeb\nMar\nApr\nMay\nJun\nJul\nAug\nSept\nOct\nNov\nDec\nPV Production\nAnnual Usage\nAssumptions\n•REC Value/kWh\n$0.00\n•Annual Inflation\n3.00%\n*Current kWh Energy Costs\n$0.56\n⚫PV Degradation\n0.70%\n*System Life / years\n25\n*Inverter Life / years\n20\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075449\n", "char_count": 869}, {"efta_number": "EFTA01075445", "page_number": 5, "text_content": "Financial Analysis\nINFLATION\nTAX BRACKET\nIRR\nANNUAL\nSOLAR\nPRODUCTION\n3.00%\nUTILITY COST ANNUAL\nS/KWH\nSOLAR\nVALUE\nO&M\nINVERTER\nREPLACEMENT\n30%\n17.35%\nREBATES,\nCASH FROM\nOTHER\nSOURCES\nITC (30% OF\nGROSS COST)\nBONUS DEP.\n50%\nMACRS 5\nANNUAL\nREVENUE\nCUMULATIVE\nCASH FLOW\nYEAR\n-$609,721\n-$609,721\n0\nSO\nSo\nSO\n1\n164929\n$0.560\n$92,360\n-$2,536\n$36,583\n$58,533\n$36,583\n-$573,138\n$148,358 -$424,780\n2\n163774\n$0.577\n$94,465\n-$2,612\n$35,120\n3\n162628\n$0.594\n$96,618\n-$2,690\n4\n161490\n$0.612\n$98,820\n-$2,771\n$21,072\n$21,072\n$126,973 -$297,807\n$115,000 -$182,807\n$117,121\n-$65,686\n5\n160359\n$0.630\n$101,072\n-$2,854\n$10,536\n$108,754\n$43,068\n6\n159237\n$0.649\n$103,375\n-$2,940\n$100,436\n$143,504\n7\n158122\n$0.669\n$105,731\n-$3,028\n$102,704\n$246,207\n8\n157015\n$0.689\n$108,141\n-$3,119\n$105,022\n$351,230\n9\n155916\n$0.709\n$110,606\n-$3,212\n$107,393\n$458,623\n10\n154825\n$0.731\n$113,126\n-$3,309\n$109,818 $568,441\n11\n153741\n$0.753\n$115,704\n-$3,408\n$112,297\n$680,737\n23154222222222\n152665\n$0.775\n$118,341\n-$3,510\n$114,831\n$795,569\n151596\n$0.798\n$121,038\n-$3,615\n$117,423\n$912,991\n150535\n$0.822\n$123,797\n-$3,724\n$120,073 $1,033,064\n149481\n$0.847\n$126,618\n-$3,836\n$122,783 $1,155,847\n16\n148435\n$0.872\n$129,504\n-$3,951\n$125,553 $1,281,400\n17\n147396\n$0.899\n$132,455\n-$4,069\n$128,386 $1,409,786\n18\n146364\n$0.926\n$135,474\n-$4,191\n$131,283 $1,541,068\n19\n145339\n$0.953\n$138,561\n-$4,317\n20\n144322\n$0.982\n$141,719\n-$4,446\n143312\n$1.011\n$144,949\n-$4,580\n-$44,678\n142309\n$1.042\n$148,252\n-$4,717\n$134,244 $1,675,313\n$137,273 $1,812,585\n$95,691 $1,908,277\n$143,535\n$2,051,811\n141312\n$1.073\n$151,631\n-$4,859\n$146,772 $2,198,584\n140323\n$1.105\n$155,086\n-$5,005\n139341\n$1.138\n$158,621\n-$5,155\n$150,082\n$2,348,665\n$153,466 $2,502,132\n3794767\n0.8167\n$3,066,065\nSo\nSo\n$182,916\n$3,111,853\nKWH\nAVERAGE\n$3,000,000\n$2,250,000\n$1,500,000\nCash Flow\n$750,000\n$0\n-$750,000\n0\n5\n10\n15\n20\n25\n25\nANNUAL REVENUE\n-\nCUMULATIVE CASH FLOW\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075450\n", "char_count": 1960}, {"efta_number": "EFTA01075445", "page_number": 6, "text_content": "Conceptual Design-Layout and Structural\nSystem Layout and Comments on Design\nThis preliminary layout will provide clean, quiet energy for approximately 20% of the property. The\nproposed arrays have been designed to be hidden from view as much as possible, maintaining the\nnatural beauty of the island. The solar system will be grid-tied. All hardware will be aluminum/stainless\nsteel for corrosion resistance. Mounting hardware and solar modules will be engineered to appropriate\nbuilding codes for wind loading. The solar structure will be designed to resist uplift values for the site.\nA backup system may be designed to provide some/all of the energy needs throughout the year. This\nwill require additional consulting to determine typical energy requirements during a power outage such\nas identifying critical loads and time of use. This system allows the owner all the benefits of using the\nutility while it is available and all the security of independence from WAPA during grid failure. The\ninverters will switch automatically within 20 milliseconds to off-grid mode, allowing for continual usage of\nyour solar asset.\nShading Considerations\nThe PV modules located at the Mechanical Buildings are in full sun throughout the day.\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075451\n", "char_count": 1332}, {"efta_number": "EFTA01075445", "page_number": 7, "text_content": "Preliminary Design- Electrical Considerations\nSite's Electric Data (assumptions)\nElectrical Service: The electrical service is: 3-phase, 208V. There is one main meter for the entire property. Line\nloss from this underwater cable is significant and will need to be factored in to further analysis. It is assumed the\nexisting electric service will support the interconnection of the proposed PV system.\nUsage Data and Electric Rate Assumptions\n-The estimated consumption of the whole complex is approximately 828,265 kWh/yr.\n- The large volume of consumption can be offset by the use of solar PV and the excess generation can be fed\nback into the utility grid at any point in the year.\n-A starting rate of $0.56 per kWh calculated from the usage and cost information typical to WAPA will be used\nfor economic projections assuming a 3.00% inflation of the cost of energy averaged over 25 years.\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075452\n", "char_count": 990}, {"efta_number": "EFTA01075445", "page_number": 8, "text_content": "Typical Project Schedule*\nDay\nDuration\nDesign & Permit 0\n45\n45\nRebate Application\n7\n45\n38\nOrder Materials 7\n60\n53\nInstallation 60\n75\n15\nInspection & Commissioning 75\n90\n15\n*Specific schedule to be outlined in contract.\nWEEK 1 2\n3\n4\n5\n7\n8\nDesign & Permit\nRebate Application\nOrder Materials\nInstallation\nInspection & Commissioning\n10\n11\n12\n10\n6\nOther Assumptions:\nThis proposal assumes a building site that is ready to begin construction of the PV mounting system. Site\nwork such as roof repairs, clearing of brush, debris removal or grading is not included.\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075453\n", "char_count": 655}, {"efta_number": "EFTA01075445", "page_number": 9, "text_content": "Back Up Option\nThe Sunny Island inverter is designed for off-grid and grid-tied battery back up systems. During grid failure, a grid-tied\nsystem will shut down to eliminate the risk of back-feeding power into the grid, posing a safety hazard. Without a\nbackup system, power produced by the PV array will not be available for use. The addition of a back up system will\nautomatically switch the grid-tied system to \"off-grid\" mode and seamlessly provide uninterrupted power supply to the\nuser. The Sunny Island back up inverter will harvest power from solar, wind, hydro, battery or fueled generator for\nuse. Renewable energy takes first priority, battery takes second and when these are no longer sufficient, the\ngenerator is automatically started and regulated to maintain adequate power supply. The battery can be sized to\nsupply enough power to run the desired loads through the night or for several days, thereby minimizing the need to\nrun a generator. Alternatively, the Sunny Island back up system can be designed with a minimum battery of 48V,\n100Ah to keep it functioning during a grid failure. Thus, the building would run on \"solar by day\" and \"generator by\nnight\" with minimal storage.\nIt is estimated that electricity from a diesel generator will cost -$0.40/kWh (cost of fuel, O&M, replacement, etc.) not\nto mention the environmental and noise pollution. The cost of solar is as little as $0.11/kWh and requires no fuel and\nvery little maintenance. Manufacturer's warranties are as high as 25 years. If grid failure is a concern, this may be a\nsmart investment for low cost energy with a high impact on reducing carbon emissions.\nThe Sunny Island back up system will add approximately 20% to the cost of your PV system and will qualify for all tax\nincentives offered for renewable energy.\nA video of the system can be viewed at:\nhttp://www.sma-america.com/en_US/news-information/videos-animations/videos-animations-sunny-island.html\nPV arrays\nSUNNY BOY*12\n3000-7000\n11+12\nCritical\nAC load\n... [truncated, 2300 chars — for the full page use /api/corpus/document/EFTA01075445/9 or ?id=EFTA01075445&page=9]", "char_count": 2300}, {"efta_number": "EFTA01075445", "page_number": 10, "text_content": "Monitoring\nAll Pure Logic Solar Systems include remote monitoring. This allows the user to know exactly what's going on with the\nsystem. It will provide real-time readings of DC voltage, AC power output and many other valuable parameters. This\ninformation will also be available on a web-based server that will allow users or technicians to troubleshoot from a\ndistance, minimizing costly service calls. It will also send out an alert if anything is functioning abnormally. This\nnotification can save hundreds of dollars in lost production which otherwise might not be noticed for a month or more.\nRemote monitoring gives the user peace of mind that the solar asset is performing. It will also be an educational tool for\nothers to get real-time working knowledge of the power coming from the sun.\nWeather Station (optional)\nThe Sunny Sensorbox is installed directly onto solar modules and measures irradiation and temperature. In\ncombination with Sunny WebBox and Sunny Portal, it provides continuous meteorological and power production data.\nThis makes it possible to detect shade, dirt, and gradually declining array performance, providing security against lost\nyield. An optional sensor to measure ambient temperature or wind speed provides even more data.\nSUNNY WEBBOX\nReliable\nResponsive\nNew-Miendly\nfiguration of the\nIncludes free onderd\nSMA\nSUNNY SENSORBOK\nInformative\nSUNNY WEBBOX\nRemote monitoring and maintenance of large solar power plants\nSUNNY SENSORBOX\nThe weather station for PV systems\nConvenie\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075455\n", "char_count": 1609}, {"efta_number": "EFTA01075445", "page_number": 11, "text_content": "Solar Modules\nHow solar works\nInverters\nElectrical Panel\nUtility Grid\n1. Solar Modules\nSolar modules are usually mounted on your roof, but can also be installed on the grounds of your property or on an\nadjacent structure such as a garage. The panels are comprised of photovoltaic cells that convert sunlight into DC\npower.\n2. Inverter\nThe power generated from the modules is sent to an inverter which converts the DC power into AC power;\n\"standard\" household electricity identical to what you receive from the utility grid.\n3. Electric Panel\nAC power from the inverter travels to your electric service panel or breaker box. The system is connected to your\nservice panel through a circuit breaker and is then distributed to any electric loads in your home.\n4. Utility Meter\nWhenever your solar system provides more power than you are currently using in your home, the excess power will\nflow into the grid through your electric meter. This will cause your meter to run backwards earning you a credit with\nthe utility company.\n5. Utility Grid\nYou remain connected to the utility grid so power is always available when you need it, even at night and during the\nday when your demand exceeds your solar production.\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075456\n", "char_count": 1307}, {"efta_number": "EFTA01075445", "page_number": 12, "text_content": "Environmental Impact\nA commercial solar system-100kW will offset over 3,250,000 lbs of carbon dioxide over 15 years, saving\nthe equivalent of:\n⚫ Driving a car 4,200,000 miles\nCO2 absorbed by 3000 trees\n⚫ 1,000,000 gallons of water used in electricity\nEnvironmental Considerations\nThe conservation of fossil fuels, the reduction of pollutants, reduction of waste, and higher efficiency usage of electricity are the\nmain environmental objectives to which Solar achieves each of these ends.\nThe Conservation of Fossil Fuels\nThis is a simple, yet important effect of using Solar Energy. As more and more individuals, corporations, and government use\nalternative energies such as solar, we conserve fossil fuels and other natural resources that are quickly diminishing. With a rapidly\nexpanding world economy, and the strong growth in highly populated countries - the demand for energy is increasing at an\nalarming rate. This makes conserving our resources more important than ever.\nIn addition to the deterioration of land, air and water - the rapid depletion of natural resources \"further compromises the ability of\nfuture generations to meet their own needs\".\nThe Reduction of Pollutants\nElectricity production in the US Virgin Islands is dominated by fossil fuels-98% coal, 2% petroleum and other like fuels. Overall\nenergy production (heat, electricity, etc.) is also dominated by these fuels (51% coal, 16% natural gas and 3% petroleum). The\nresulting CO2 emissions come from coal (81%), gas (15%), and from petroleum (4%).\nThere are major environmental impacts attributed to electricity generation from these non-renewable fuels. Emissions of pollutants\ninto the atmosphere (particulates, Sulphur Dioxide (SOX), Nitrogen Oxide (NOx), Carbon Dioxide (CO2), and others) all have a\ngrave impact on public health, water and crops. These negative externalities also impact many delicate ecosystems such as\nforests and fisheries.\nThe Reduction of Waste\nElectricity produced from Coal (the primary source \n... [truncated, 3726 chars — for the full page use /api/corpus/document/EFTA01075445/12 or ?id=EFTA01075445&page=12]", "char_count": 3726}, {"efta_number": "EFTA01075445", "page_number": 13, "text_content": "Proposal Acceptance and Letter of Intent\nJeffrey Epstein, Mechanical Buil\nLittle Saint James Island\nLittle Saint James, USVI 00802\nProposal Summary\nSystem Size\nContract Cost\nAnnual Production\nLocation\nSolar Installation Agreement\n120.8 kW DC\n$609,720.84\n164,929 kWh\nRoof and Ground\nWith the acceptance of this proposal, Pure Logic will prepare a formal Solar Installation Agreement in accordance\nwith the equipment and pricing specifications laid out within this Proposal. When issued, the Solar Installation\nAgreement will replace this Proposal Acceptance and Letter of Intent. No physical labor or order of material is to be\nperformed until a fully signed and executed Solar Installation Agreement is received from Buyer.\nPayment Schedule\nA Progress Payment Schedule will be included in a Project-Specific Rider.\nCancellation\nBuyer has the right to withdraw his/her Proposal Acceptance and Letter of Intent should the terms of the Solar\nInstallation Agreement be deemed unacceptable to Buyer for any reason, or if Buyer is unable to secure\nacceptable financing.\nAuthorized Signature(s)\nX\nCustomer Signature (\"Buyer\")\nPrint Name\nX\nDate\nX\nCustomer Signature (\"Buyer\")\nDate\nPrint Name\nPure Logic Clean Energy Quote | Office: |\n| Fax:\n| Web: www.purelogiccleanenergy.com\nEFTA01075458\n", "char_count": 1282}]}