{"efta_number": "EFTA00840335", "page_count": 2, "url": "https://epstein-data.com/EFTA00840335", "pdf_url": "https://epstein-data.com/pdf/EFTA00840335.pdf", "pages": [{"efta_number": "EFTA00840335", "page_number": 0, "text_content": "From: \"jeffrey E.\" <jeevacation@gmail.com>\nTo: Larry <\nSubject: Re: KBAF\nDate: Fri, 20 Nov 2015 09:23:11 +0000\nyes of course. but will that fix the voltage fluctuation? can we overfly into alberqueqye\nOn Thu, Nov 19, 2015 at 11:53 PM, Larry\nJeffrey,\nwrote:\nAttached is video from today's flight showing voltage and pressure fluctuations on right precooler, with\nthrottles reduced, pressure and voltage remains steady with throttles at higher power setting the voltage and\npressure fluctuated on right. See Pete's message below.\nWith your approval, we will change Temp sensor, cost $4,000 before flight Friday.\nHi Larry,\nHere is the schematic for the system.\n-From the videos-\nThe pressure reading is what controls the valve position. The valve is responding to the voltage signal from the\ncontroller. Fail safe open, no pressure/voltage applied, valve is open.\nAs you can see in the video, the voltage supplied to the torque motor, which then positions the valve, is all\nover the place.\nThe valve then is trying to open/close as requested. That explains the PSI changes, disregard the delay in the\ndisplay, it follows the voltage.\nThe later video- on descent, with lower power settings, has the readings steady, the same readings on both\nsides.\nI don't see an issue with the controller, as I originally thought.\nThe controller is sent input from the temp sensor, and anticipator. Both are original. The sensor is about $4K. I\nwill have it replaced prior to the trip. The anticipator is $77K, will hold off on that replacement for now.\nI would prefer that we do one item at a time- if the issue goes away with the new sensor- great!\nIf the issue remains- I would recommend swapping the Anticipators, to prove anticipater is at fault.\nLate night thought-\nThe sensor makes the most sense,\nThe issue seems to be at higher power settings when the system is looking at both sensors. At high power\nsettings, the system uses the anticipator first, the temp sensor is set to maintain the 400 degree set point. If it\ndoesn't see the setting point, could it send a low temp signal to the controller and allow the anticipator to try to\nbring it back to 400, then the anticipator would command it back open/closed. A back and forth scenario, like\nwhat I saw on the displays.\nOn power back, the 400 degree sensor can't react, since the engine air supply is below that point.\nPete\nSent from my iPad\nBegin forwarded message:\nEFTA00840335\n", "char_count": 2422}, {"efta_number": "EFTA00840335", "page_number": 1, "text_content": "From: Pete Rawson\nDate: November 19, 2015 at 3:54:44 PM EST\nTo:\nSubject: KBAF\nPete Rawson\nI had to trim the video\nHere is toward the end in low alt cruise. 14k ish at 300 kts\nPete Rawson\nChief Inspector\nMeridian Jet Center\nplease note\nThe information contained in this communication is\nconfidential, may be attorney-client privileged, may\nconstitute inside information, and is intended only for\nthe use of the addressee. It is the property of\nJEE\nUnauthorized use, disclosure or copying of this\ncommunication or any part thereof is strictly prohibited\nand may be unlawful. If you have received this\ncommunication in error, please notify us immediately by\nreturn e-mail or by e-mail to jeevacation@gmail.com, and\ndestroy this communication and all copies thereof,\nincluding all attachments. copyright -all rights reserved\nEFTA00840336\n", "char_count": 834}]}