{"efta_number": "EFTA00829680", "page_count": 3, "url": "https://epstein-data.com/EFTA00829680", "pdf_url": "https://epstein-data.com/pdf/EFTA00829680.pdf", "pages": [{"efta_number": "EFTA00829680", "page_number": 0, "text_content": "From: Pete Rawson\nTo: jeffrey E. <jeevacation@gmail.com>,\nSubject: Re:\nDate: Sat, 09 Apr 2016 23:02:09 +0000\nHello Jeffrey,\nLarry knows that I am long winded with my responses,\nHere is my brief-\nFeel free to read all at your leisure-\nThey are mostly my thoughts so far-\nI suspect that the right precooler (fan air) modulating valve is bad.\nThey are both original.\nFrom the last video and Photo's;\nThe readings show that the left side is being given a voltage to the Torque motor sending a pressure to\ncommand the valve to be partially closed.\nZero volts, zero pressure is for full open, ie: cold air into the precooler and lowering the temperature into the\nsupply system.\nThe signals show a steady state condition; 3 Volts, 3 PSI.\nThe valve has been sent signals, and has responded correctly, and therefore is in the proper position to\nmaintain 400 degrees in the supply system.\nThis is being monitored, and controlled by the controller, and the sensor inputs.\nThere is no signal from the valve, the temperature monitoring circuit controls the changes required.\nThe right side shows that it is being commanded to close due to the high voltage, and pressures.\n(9 volts, 9 PSI)\nIt seems that the signals are not being followed, or that the valve cannot respond to them.\nSince the control system does not see the temperature change from the sensors, it continues to increase the\npressure to the valve.\nBrief complete-\nAs for the full version-\nThis was done as a draft, please excuse any duplication for items noted in the brief, these were my original\nthoughts.\nI agree with all that you stated-\nThe guidelines are for what the electrical system does.\nWe have found a bad controller- the sweeping voltage and pressures, and replaced it-\nThere was also a bad sensor that was replaced-\nWe have swapped the pressure regulator/torque motors.\nLatest swap was the Anticipators.\nEFTA00829680\n", "char_count": 1882}, {"efta_number": "EFTA00829680", "page_number": 1, "text_content": "There seem to be multiple issues, and we are narrowing them down.\nI believe that the electrical and control systems are now operating normally.\nNow on to the air side of it.\nFrom the last video, and photo's-\nI believe that the left side is operating properly.\nThe Temp is being controlled by sending a regulated pressure to the valve, and it responding.\nThe pressure supplied is closing the valve, and maintaining the 400 Degrees requested.\nNo voltage equals no pressure, Valve open, lowering the Temperature.\nThe right side shows giving a close signal to the precooler (fan air) valve.\nHigh Voltage, and pressure supplied to the Valve on that side to close, and increase the temperature.\nThat side doesn't seem to respond.\nThe valve has a 4 inch input/output side.\nThe control line is about 1/4 inch.\nThat is one of the lines that we found collapsed, and started us on this direction.\nIs it possible that the supply air is not being able to overcome the pressure at the valve?\nThe pressure read at the panel is a control pressure, also known as \"Muscle air\".\nMaybe the input air at the 4 inch diameter inlet, can overcome the control air.\nI again suspect an issue with the LP valve-\nThere is no valve position, or feedback signal from the valve-\nThe electrical signal is showing to close the valve,\nThe pressure is also showing to close the valve.\nOne way to check is to select Wing heat on-\nThe system causes the applicable side to remove the signals, and allow the valves to go full open.\nWing heat is not normally used at altitude-\nWhen the aircraft is in below 0 degrees temps, there is no reason, since any precip won't stick.\nAsk Larry if there any issues with selecting the wing heat on at altitude-\nI don't believe that there are any limits to the altitude, but the fuel burn will be increased.\nJust a quick check-\nThe ground checks for the precooler system are limited,\nEngines running, there should be no air flowing from the lower pylon heat exchanger at idle-\nIncrease power, and there should be airflow noticed.\nMy training manual shows that the valve should start to open at about 74% HP on the ground,\nWing heat on, there should be airflow.\nRegards,\nPete\nFrom: jeffrey E. <jeevacation@gmail.com>\nSent: Saturday, April 9, 2016 10:13 AM\nTo:\nSubject:\nPete Rawson\nEFTA00829681\n", "char_count": 2289}, {"efta_number": "EFTA00829680", "page_number": 2, "text_content": "The precooler fan air modulating valve (installed in the engine pylon) controls fan air airflow to the precooler in\norder to maintain a nominal 400° F (204° C) bleed air temperature. Precooler outlet air temperature is\ncontinuously monitored by a precooler outlet temperature sensor and a precooler temperature control\nanticipator sensor. Outputs from these sensors are transmitted to the precooler temperature controller. The\ncontroller, in turn, will change the output voltage to the servo air pressure regulator and torque motor. The\nservo air pressure regulator and torque motor then changes the electrical signal to a filtered pneumatic signal,\npositioning the precooler fan air modulating valve accordingly\nplease note\nThe information contained in this communication is\nconfidential, may be attorney-client privileged, may\nconstitute inside information, and is intended only for\nthe use of the addressee. It is the property of\nJEE\nUnauthorized use, disclosure or copying of this\ncommunication or any part thereof is strictly prohibited\nand may be unlawful. If you have received this\ncommunication in error, please notify us immediately by\nreturn e-mail or by e-mail to jeevacation@gmail.com, and\ndestroy this communication and all copies thereof,\nincluding all attachments. copyright -all rights reserved\nEFTA00829682\n", "char_count": 1324}]}