{"efta_number": "EFTA00639158", "page_count": 2, "url": "https://epstein-data.com/EFTA00639158", "pdf_url": "https://epstein-data.com/pdf/EFTA00639158.pdf", "pages": [{"efta_number": "EFTA00639158", "page_number": 0, "text_content": "From: Richard Kahn\nTo: Jeffrey Epstein <jeevacation@gmail.com>\nCe: Ann Rodriquez <\nSubject: Fwd: Larger unit in master bedroom\nDate: Tue, 27 Oct 2015 16:53:46+0000\nPlease advise\nSent from my iPhone\nBegin forwarded message:\nFrom: reefcoservices\nDate: October 27, 2015 at 10:06:17 AM EDT\nTo: Ann Rodriquez\nCe: richardkahn12<\nSubject: Larger unit in master bedroom\nHello Anna,\nYou have asked me to upgrade the master bedrooms AC to a larger one so that the\ntemperature can be lowered to 62 degrees Fahrenheit. I can do that, however there are\nsome issues that occur when this is done and which need to be addressed.\nA properly functioning and properly sized central air conditioning unit should be able to\nmaintain the temperature of your house at any reasonable temperature you select.\nThe amount of cooling available is related to the size of the system, insulation in the\nhouse, and the outside air temperature. Residential A/C units are manufactured,\ndesigned and sized to make the room temp 20-25 degrees below the outside temp. So if\nthe outside temp is 95 deg., then the room should be able to cool efficiently to 70. As\nthe outside temp increases then the inside increases proportionally.\nWhen an air conditioner runs, it has two functions. First, it lowers the temperature of\nthe air, and secondly, it removes moisture from the air. To be able to perform this\nsecond job, the AC has to run for a while. As the air passes over the evaporator coil, it\nencounters a very cold surface. Ideally, when the air passes over that cold surface, the\nair temperature drops approximately 20° F.\nIn regions where we have higher relative humidity (like in the Caribbean, for most of\nthe year), the other important process that happens when the air hits the coil is that the\ntemperature of the coil is below the dew point of the air. As a result, water vapor\ncondenses on the coil. Yet, here lies the concern. Water vapor condenses on coils in\nover-sized air conditioners, too, but there has to be enough condensation on the coil for\nthe water to begin dripping down into the pan below the coil. Even then, you're not\nthere yet. You still have to have enough water in the pan for it drain to the outside.\nUntil the water that condenses actually makes it to the outside, you haven't really\ndehumidified the air. This is because that water on the coil can evaporate and return\nEFTA00639158\n", "char_count": 2378}, {"efta_number": "EFTA00639158", "page_number": 1, "text_content": "into the air in the home, which causes the moisture to stay in the room, effecting\nfurniture, electronics, etc. Additionally, fungi can grow on the walls, in furniture, and\nclosets.\nOver-sized air conditioners do not run for a long time because they satisfy the cooling\nload quickly and then turn off. Properly sized air conditioners run longer, so if you want\nyour air conditioner to dehumidify your home as well as cool it, you do not want to\noversize the unit.\nThe process that wears out the equipment is frequently starting it up and shutting it\ndown. The more this happens, the shorter the life of the equipment. When an AC is\nover-sized, it starts up and shuts down a lot more because it runs for only a short time\nto meet the thermostat set point. Then a few minutes later, it turns on again and runs\nfor another short period of time. Over the course of a day, an over-sized air conditioner\ncan have a lot more start-ups and shut-downs than a properly sized air conditioner.\nWhich indicates that you will probably be repairing it more often and replacing it sooner.\nI have installed low temp. systems before in hospitals and laboratories, but we use a\nvapor barrier in the floor, walls, and ceilings. Then we have to add make up air to the\nroom due to the lack of air exchange because of the vapor barriers. After this, all the air\nis run through a dehumidifier before it is discharged into the room. Those rooms can be\ncooled to the 50s and with all of the added precautions taken just mentioned, it's not a\nproblem. To do that here in the Caribbean, with our outside temperatures and humidity,\nto a concrete room is asking for some problems.\nHowever, If you still wish to proceed, I will come out and assess what will be needed to\ninstall a larger unit in the master bedroom.\nRegards,\nDavid Van Drieson\nEFTA00639159\n", "char_count": 1825}]}