{"efta_number": "EFTA00629960", "page_count": 2, "url": "https://epstein-data.com/EFTA00629960", "pdf_url": "https://epstein-data.com/pdf/EFTA00629960.pdf", "pages": [{"efta_number": "EFTA00629960", "page_number": 0, "text_content": "From: Larry Visoski\nTo: Je vacation <jeevacation@gmail.com>\nSubject: GIV pylon update\nDate: Fri, 08 Apr 2016 23:33:21 +0000\nJeffrey,.\nI spoke to Pete,. Here is latest from him,.\nThe air that is exhausted overboard thru the Pylon precooler comes From inside engine cowling from FAN duct\nBleed air, it's regulated by LP \"Fan Air\" valve,. See Petes description for system operation below, he\nrecommends swapping duct temperature sensor again for the system.\nLarry,\nAs to the air system problems-\nI suspect that all of the control and monitoring systems are working properly-\nYou may wish to swap the Temp sensors prior to next flight to TEB.\nOne was replaced by me a while ago-\nThey are the ones on the duct's in the hell hole-\nThey are one of the 3 that I showed you-\nTemp sensor on top,\nBleed duct overheat switch middle,\nAnticipator on the bottom.\nThey have a \"Click\" on connecter, 9/16 wrench is the only tool needed.\nRecord the P/N and S/N's if you swap them.\nI believe that the left side is operating properly-\nIt seems to be controlling the LP air valve to maintain a slightly open position-\nIt should be regulating to 400 degrees- (F)\nYou mentioned that the engine's TGT were around 500 Degrees-(that's about 900 degrees F)\nThat is registered in \"Celsius\", and is after the combustion process,\nThe bleed air system is taken prior to the combustion stage, and is in Fahrenheit.\nIf the bleed air system on the left sensed 425F, it would send a lower electrical signal to lower the\nvoltage/pressure to allow the LP valve to open slightly.\nFull closing would be higher voltage, and pressures, such as seen on the right-\nValves are full open, ie: full cold, with no input-\n3 volts/psi, would equate to allowing the valve to be partially open, cooling the bleed air to 400 degrees.\nThe valves do not show the actual position, the panel only shows the signals input to them for control-\nThey are not an open/closed valve, they are modulating valves, being commanded to variable positions from the\ncontroller.\nI believe that the right side is trying to close the valve, to get the 400 degrees, and we are seeing the high voltage,\nand pressure at the panel,\nbut the valve may not be responding to the signal-\nThe system does not see the proper temperature at the sensors causing the reaction, so it continues to increase the\ncommand signal.\nOn the ground, the checks are for no airflow over the precooler at idle, and \"some\" airflow when anti-ice is\nselected.\nThe system has been checked by me, and at Westfield, doing the swap of the Torque Motor Operational checks.\nEFTA00629960\n", "char_count": 2577}, {"efta_number": "EFTA00629960", "page_number": 1, "text_content": "The pictures/video show that the right side is trying to close the LP valve, and decrease the Temp to the bleed air\nsystem input.\nAt idle, doing the normal checks, the pressure into the valve is low-\nThe valve is spring loaded open anyway-\nThe line that we replaced at the start of this project is part of the input to the valve-\nThere may be an air leak in the line from the Torque motor to the valve-\nFrom hell hole, through pylon, to valve, allowing the pressure to bleed off and not closing the valve.\nThe right LP- \"Fan air\" valve my be at fault-\nThere is pressure applied from the duct- 4 inch- to the valve, maybe 5 psi at idle, but unknown at normal power\nsettings in flight-\nMaybe the pressure at the 4 inch line is too much for the control input air- internal leaking?\nThe pressure on the panel are what is being supplied to the valve.\nThere could be an issue with the internals of the right valve-\nOK with low input pressure, but can't' handle the higher pressures involved at higher power, or a possibly a cold\nsoak item.\nCut to the chase-\nNext idea is to swap the left and right Precooler \"fan air\" valves left to right.\nTime intensive, since the pylon panels need to be accessed for each.\nWe should be able to disconnect and leak check the lines from the torque motors to the valves.\nthis is from \"Tail Chaser\"\nRegards,\nPete\nSent from my iPad\nEFTA00629961\n", "char_count": 1370}]}