{"efta_number": "EFTA00599815", "page_count": 1, "url": "https://epstein-data.com/EFTA00599815", "pdf_url": "https://epstein-data.com/pdf/EFTA00599815.pdf", "pages": [{"efta_number": "EFTA00599815", "page_number": 0, "text_content": "FOOTING LEGEND\nF1-36\" x 36\" x 12\" DP. FORMED\n(W/ #4 REBAR @ 8\" O.C. E.W.)\nALL FTG TOPS 4\" BELOW SLAB TYP.\nBASEMENT FDN/STRUCT FLR PLAN\nSITE PLAN INFO PREPARED BY FRANGIONE ENGINEERING, LLC\nNEW CANAAN, CT TO BE SUBMITTED UNDER SEPARTE COVER.\n1/4\" SCALE\nFRAMING NOTES\nBLUE LINK: BASE BID AS SPEC'D ON\nIMPROVED PERFORMANCE SYSTEM\nFLOOR JOIST SYSTEM TO BE USED\n40 PSF LIVE LOAD 20 PSF. DEAD LOAD\n(BEDROOMS: 30 PSF LL)\nNOTE: FLOOR JOISTS FRAMING. AS PER\nSTRUCT.MFR'S DETAILS FOR CONNECTIONS,\nBRIDGING CANTILEVERED CONDITION'S\nBEARING POINTS, WEB STIFFENERS\nSQUASH BLK'S,NAIL'G ETC. CONFIRM\nRESPECTIVE CUT SHEETS FOR PROPER\nINSTALLATION TECHNIQUES.\nCONTRACTOR MAY SUBSTITUTE GPI LVL BM'S SPEC'D\nWITH POWER BM, BILLET BM OR OTHER COMPOSITE\nBMS W/ EQUAL STRENGTH/CARRYING CAPABILITIES\nALTERNATE OR SUBSTITUTED FLOOR SYSTEM'S\nARE TO BE DESIGNED FOR APPROPRIATE LOADS\nAND SPANS / CONTRACTOR IS TO SUPPLY\nAPPROPRIATE SPECS FOR SUBSTITUTED\nJOIST SYSTEM TO ARCHITECT AND LOCAL CODE\nOFFICIAL PRIOR TO ORDERING MATERIALS\nJL USE EXTRA HEAVY DUTY JST.\nHANGERS AT FLUSH\nCONDITIONS\nMIN. 2 1/2\" PVC WIRE CHASE FOR FUTURE\nWIRE PULLS FROM BSMT. TO ATTIC IN WALLS\nCONFIRM W/ OWNER PRIOR TO INSTALLATION\nNOTE: PROVIDE SLEEVES FOR RESPECTIVE UTILITY\nSERVICE CONFIRM LOCATION W/SUB-CONTRACTOR\nAND OR UTILITY CO. AS REQ'D.\nNOTE: HVAC LAYOUT AND DESIGN BY\nOTHERS INSTALL AS TO MFR. SPECS\nAND TO CODE (DIRECT VENT TO EXTERIOR\nBY CODE)\nNOTE:\nPROVIDE RADON VENT'G AS PER LOCAL REQMT'S\nPROVIDE REMOVABLE ALUM GRATES ABV AT BOTH WDW WELLS\n(SUBMIT QUOTES/ALTS AT BD)\n18'-0\"\n17'-6\"\n5-4\n8'4\"\nPVC PULL\n8\" BLOCK ON CONT 8\" THK SLAB WELLS W/DRAINS\nAND CRUSHED STONE BACK FILL (PROVIDE MATCH'G\nSTUCCO WALL FIN ON INT OF EXP BLOCK AREAS)\n10'-8\nTo WELL\n(2)2x10's CONT\nTHICKEN BSMT SLAB TO 8\" UNDER THIS WALL FOR BRG\n8\" LB MSRY BLOCK OR POURED CONCRETE FON WALL ON\n20\" X 10\" POURED PATIO CONC FTG, MIN 42\" DEPTH\n4\" THK, 3500 PSF CONC SLAB OVER 6 MIL POLY\n& 4\" THK 3/4\" CRUSHED STONE BASE (STL\nTROWEL SLAB FIN, TYP)\nPATIO FIN ABV OVER 4\" CONC SLAB AND CRUSHED STONE\nBASE ON 6 MIL PLOY & 95% COMPACTED SELECTED BACKFILL\n(UNEXCAV PATIO)\nF-1 FOOTINGS: 36x36x 12\" DP W/(3) #4 REBARS\n8\" OC, EW-FORMED & POURED W/ 3500PSF CONC\nEA C-LINE OF COLUMNS NOTED\nSUMP\n18-11\"\n11 7/8\" CONT BLI 80 FJS\nGYMNASIUM\n92.00\nRUBBER FLA\nF-1\n3080 T GLASS\nFLOOR JOISTS\nINTERLOCKING RUBBER FLOOR SYSTEM\nFINISH AS SEL'D (FIELD MEAS)\nMIRRORS TO 8 FT HT ABV BASE W/CROWN MLDG\nCAP/WALL TO WALL LAYOUT & INSTALL N\nIN FIELD W/OWNER\nALL TEMPERED GLASS VISION PANELS: FIELD\nMEAS, FABRICATE, AND INSTALL W/MATCHING\nINT TRIMWORK, ESIDE (HEADS #8 FT)\n4\" STUD FRM'D INT WALLS, TYP UON\nSTEP FTGS DOWN TO MEET BOT OF\n2'-0\" 10\"\n2880\nCONT 11 7/8\" BLI 80 FJ'S\n12-2\"+/-\n10 22\"-10\"+/-\n7'4\"\n3\n(2)2x10's ESRESS WELL\n(2)2x10's\nPATIO FIN OVER 4\" CONC SLAB AND CRUSHED STONE\nBASE ON 95% COMPACTED SELECTED BACKFILL\n12\" LB MSRY BLOCK OR PORED CONCRETE FR WALL-ON\n24\" x 12\" POURED CONCRTE FTG, MIN.42 DEPTH\n(ALT FOR SUPERIOR WALL FDNS)\nMTD WALL LADDER FOR EGRESS ESCAPE\"\n8 BLOCK FDN ON 16\"X8\" CONC FTGS\nW/STUCCO FIN BASE BID (VIF)\n2\" PVC SLEEVE UNDER SLAB & INTO YARD FOR FUTURE\nWIRING PULLS (VIF ANY FINAL STUB OUTS W/OWNER)\n88\n3'-8\"\nBATH 5\n2480\nLIN\n2480\n6-1\"\n3-3\"\n11 7/8\" CONT. BLI 60 FJ'S\nEGRESS SASH W/MIN 37 SPOF\nNET CLEAR SASH OPNG\n45\n2X STUDS ON FLAT BTW EQU\nDEPTH LIN CLOSETS\nADHERE TO MIN FIXT CLEARANCE\nBY CODE, TYP\nSUMP\n92.00'\nBEDROOM 5\nCARPET\nN\n17-2\"\nSHOWER DETL'S SIM TO M BATH\nSHT #3\n45\n92.00\n5'-0\" 6\"\n2800\nPIT\nPROVIDE CONT FULL HT $X9\" LVL\nVERT CAR RAIL SUPPORTS AS PER\nMFR'S SHOP DWGS\n124\"\nREP ELEV DOMEN\n7'-9\"\nBORD\n5'-2\"\n5-11\"\n2-4\n88.833\nELEV\nEQPMT\nCOME\nm\nELEV PIT\n11 7/8\" 840 FJ'S\nWIC\nCARPET\nred/shalt\nCOL'S IN WALL TO BEAR\nON BLK BEYOND\nLAYOUT (2) VP'S W/(3) EQU JAMBS\n11 7/8 BLI 40 FJ'S\n14\" DP PIT W/8\" BLOCK ON 20x10\n& POURED 20 x10\" CONC FTG DROPPED BELOW\n4\" SLAB (VERIFY W/SEL'D ELEV MFR'S SPECS)\nPACK OUT WEBS TO RECEIVE FLUSH FJ FRAMING\nMEMBERS (STEEL JST HANGERS REQ'D, TYP)\n92.00\n3080 T GLASS\nOPEN BSMT SPACE\n11 7/8 BLI 40 FJ'S\nCARPET\nFLUSH CONT 3 1/2\"x 11 7/8\" LVL BM\n2-4\n(UNEXCAV PATIO)\n7-0\n16-0\n16'0\"\nPREFAB SUMP PITS/PUMPS AS SELD UNIT W/REMOVABLE COVERS\n-FLUSH W/FIN FLR LEVELS (TIE TO INT DRAIN PIPING, TYP)\n4\" STUD FRMD INT WALLS, TYP UON\nVERIFY ELEV MFR'S REQMT FOR EQUIPT\nROOM LAYOUT\nTHREE STOP, HYDRAULIC RESIDENTIAL ELEVATOR\nAS SEL'D (PROVIDE FIELD MEAS/SHOP DRAWINGS\nFOR APPROVALS)\nDOTTED CURVED MSRY STEP ABV/LAYOUT\nIN FIELD\nPROVIDE FIN CARPET EDGE STRIPS AS SEL'D\nTO JCT DISSIMILAR FLOOR TRANSITIONS, TYP\nFOUNDATION SYSTEM: BASE BID ON SUPERIOR 10\" PREFAB\nWALL UNITS, SYSTEM, AND STONE FOOTING (PROVIDE SHOP\nDWG SUBMISSIONS SEALED BY CT ENGR)\nALT POURED 10\" THK 4000PSF CONCRETE W/ STEEL REINF AS\nPER DETAIL SHEET #7 (SUBMIT $$ @ BID FOR COMPARISON)\nBASE BID: R-21 FGL INSULATE AND ADHERE 1/2\" GWB WALL FIN\nTO SUPERIOR WALL FLANGES (ALT: TO FURR CONC WALL OR ADD\nSTUDS, STYROFOAM INSUL, AND APPLY GWB OVER FURRING/STUDS)\nRECESS WALL STUD FMG IN ALCOVE ABV FOUNDATION/FLOOR\nABV. FLASH @ EXT STONE REVEAL (SEE ELEV)\n5/4\"x3\" 16\" 0.C.\nGRADE\n1/2\" GWB T & S TYP.\nFIRESTOP REQUIRED\nMATERIAL CHOICES ARE:\nA. 5/8\" TYPE 'X' FIRERATED G.W.B.\nB. 3/4\" PLYWOOD\nC. FIRE SAFING\n1/2\"\nPROVIDE 1/2\" CLEARANCE (MIN)\nR-11 INSULATION WITH\nVAPOR BARRIER\n1/2\" G.W.B. FINISH\nFRAMING 16\" O.C. / WOOD OR\nSUB 25 GA METAL STUDS @\nNON-BEAR'G WALLS (ALT TO FURR\nMSRY FDN)\nP-TRD PLATE REQUIRED IF\nWOOD FRAMING IS USED (TYP)\nTRIM AS SEL'D BY OWNER\nHSE FDN/FTG (24\" MAX STEP AT 2T01\nSLOPE TYPICALLY)\n23'-0\"\n3\" PVC SLEEVE HERE UNDER SLAB INTO YD FOR\nFUTURE WIRING PULLS (VIF W/OWNER)\n5'10\"\nCLOSET\nCONC\nROUGH SANT/WATER PLUB'G FOR FUTURE BAR SINK\nAND PROVIDE FUTURE STUB UP CONN UNDER STONE\nPATIO FIN (PROVIDE FULL DRAIN DOWN CAPABILITY)\n2X8 FRM'D LAND'G ONE STEP DN FROM MAIN\nLEVEL ABV\n7880\n7'-7\"+/-\nENTRY\nCARPET\n92.00'\nCONT S 1/2\"x 11 7/8\" LVL FLUSH\n(OPEN FOR\nSTAIRS)\n11 7/8\" CONT BLI 40 FJS CONT\n\"\nALIGN FDN FACE W/INT OF STUD WALL ABV TO INSTALL STR CARRIAGE\n8/8.25\" RISERS/9.5\" TREADS AT OAK STAIRS TO ABV. (34\" HANDRAIL\nAS SELECTED TO MEET CODE DETAILING) PROVIDE SHOP DWGS, TYP\n(UNEXCAV GARAGE ABV)\n1 LAYER 5/8\" 1 HR GWB INT UTILITY ROOM FINISH AT WALLS\nAND CEILING (TSP FIN)\nEXTEND B-VENT EHXT FLUE(S) FOR OIL FURN/HWH TO MTL DUCT UP THRU\nROOF INTO CHINMEY ABV. VENT AND CLEAR REQMTS AS PER CODE\nHALL\nCARPET\n10°\n2-4\n5-10\nWH\n3080\nOIL FIRED HVAC AIR SYSTEMS: (BSMT UNIT W/DEHUMIDIFER & 1ST FLR UNIT) DESIGNED AND\nINSTALLED BY OTHERS/PROVIDE BALANCE CHECK AND A FINAL BAL REPORT TO OWNER\nFURN\nUTILITY\nCONC\nUTILITY SLEEVES AS REQ'D BY RESPCTIVE UTIL CONN (VERIFY @ BID)\n12\" LB MSRY BLOCK OR POURED CONCRETE FON WALL ON\n24\" x 12\" POURED CONCRTE FTG, MIN 42\" DEPTH (STEP\nALT:FURRED WALL DETAIL (TYP)\nSCALE 1/2\"-1'-0\"\nAS REQD) ALTS: SUPERIOR WALLS AT GARAGE FDN\n23'-0\"\n11 7/8\" BLI 40 FJ'S\nDOTTED DROPPED DUCT CHASE ADJ TO DROPPED\nSTL BM (MINIMIZE TO 12\" DEPTH MAX TO SUIT DUCT\nFINAL LAYOUT CONFIGURATION) DESIGN BY OTHERS\nTHICKEN SLAB TO 8\" UNDER THIS WALL\nF-1\nADJ SHELV'G AS SEL'D\n(CONFIRM AT BID)\n-----351)\n11 7/8\" BLI 40 FJ'S\n6\" STUD TO BURY COLUMNS\n& BEAM ABV, TYP\n14-9\"\n10\nCONT FLUSH 3 1/2\"x11 7/8\" LVL BM\nPLAY ROOM\nCARPET\n92.00'\n11 7/8\" CONT BL 40 FJS CONT\nFLUSH 3 1/2 x 11 7/8\" LVL BM\n2880\nPVC PULL\n2-1\"\n7-8\nUTILITY\nCONC\nNO\nDATE\nA\nLAYOUT UTILITY ROOM W/ 5/8\" PLYWOOD\nWALL PANELS AS REQ'D (SOILD BLOCK TYP)\n2\nOIL FIRED GENERATOR TRANSFER SW/ VERIFY\nUNIT SEL 'N AND SPECS AT BID\nGALV PREFAB WELLS AT AWN'G SASH\nW/COVERS\nMIN 6 FDN BRG, typ\n8-7\nFURN\n92.00\nSUMP\n4\n6'-6\"\nPVC PULL\n18-10\n5'-6\"\nPROVIDE FON SLEEVES AND A MIN 2\" PVC WIRE\nPULL FOR FUTURE EXTERIOR ELECTRICAL WORK\nUTILITY SLEEVES AS REQ'D\nBY RESPCTIVE UTIL CO'S\n(VERFY @ BD)\nPITS REQ'D/PUMPS AS SEL'D (VIF\nW/ SITE SUBSURF COND AND SITE\nENGR'S DWGS FOR SITE DRAIN\nREQMTS\nREVISIONS\nDESCRIPTION\nTHIS DRAWING REMAINS THE PROPERTY OF THE ARCHITECT AND\nITS CONTENTS SHALL NOT BE REPRODUCED WITHOUT WRITTEN\nAUTHORIZATION\nCONTRACTOR MUST VERIFY ALL DIMENSIONS AND CONDITIONS IN\nTHE FIELD, AND SHALL COTAIN ALL OTHER PROJECT INFORMATION\nNECESSARY TO PERFORM\nUSE NUMERICAL DIMENSIONS FOR CONSTRUCTION PURPOSES\nDO NOT SCALE DRAWING PRINTS\nGROFF RESIDENCE\nNew Custom Residence\nNEW CANAAN\nHeyrich Drake\nassociate architects\nJahn Heyrich\nSarah Drake\nAN, CT\n(2)2x10's/\nBASEMENT FOUNDATION PLAN\n3'-10\n13-6\n10'-6\"\n1231\nJG\n15 AUG 2012\n11\nWING WALL/PIER FON/SEE SHT TWO\nFOR DIMEN & MATERIALS\nEFTA00599815\n", "char_count": 8255}]}