{"efta_number": "EFTA00599812", "page_count": 1, "url": "https://epstein-data.com/EFTA00599812", "pdf_url": "https://epstein-data.com/pdf/EFTA00599812.pdf", "pages": [{"efta_number": "EFTA00599812", "page_number": 0, "text_content": "5.01X2(E)\n3 1/2X 11 7/8\" LVL (MAX CANT 2 FT)\nSECOND FLOOR FRAMING PLAN\n1/4\" SCALE\n(3)2X10'S CONT\n4X6 WD POST BTW SASH,\nTYP UON\n31/2K11 7/8\" FL LVL (CANT 2 FT)\n(3)2010'S\n(3)2K10'S\n11 7/8\" BU 40 FJS\n11 7/8\" BLI 80 FJS\n6\" WALL FOR PLBG STKS\n51/2 X 11 7/8\" FLUSHLVL BEAM CONT\n6X8 PARALAM\nPOST STL BM\nBRG\nTYP FMG NOTES:\nBLUE LINX: BASE BID\nIMPROVED PERFORMANCE SYSTEM\nFLOOR JOIST SYSTEM TO BE USED\n40 PSF.LIVE LOAD 20 PSF. DEAD LOAD\n(BEDROOMS: 30 PSF LL)\nALTERNATE OR SUBSTITUTED FLOOR SYSTEM'S\nARE TO BE DESIGNED FOR APPROPRIATE LOADS\nAND SPANS/CONTRACTOR IS TO SUPPLY\nAPPROPRIATE SPECS FOR SUBSTITUTED\nJOIST SYSTEM TO ARCHITECT AND LOCAL CODE\nOFFICIAL PRIOR TO ORDERING MATERIALS/\nTRUS JOIST, GPI, IPI JOISTS ARE ACCEPTABLE\nNOTE: FLOOR JOISTS FRAMING. AS PER\nSTRUCT.MFR'S DETAILS FOR CONNECTIONS,\nBRIDGING CANTILEVERED CONDITION'S\nBEARING POINTS, WEB STIFFENERS\nSQUASH BLK'S, NAIL'S ETC. CONFIRM\nRESPECTIVE CUT SHEETS FOR PROPER\nINSTALLATION TECHNIQUES.\nLUSE EXTRA HEAVY DUTY JST.\nHANGERS AT FLUSH\nCONDITIONS\nCLIP ANGLES BOLTED-\nCORNERS NOTED, TYP\n71/2 X 11 7/8\" FLUSH LVL BEAM CONT\n51/2 X 11 7/8\" FLUSHLVL BEAM CONT\n11 7/8 BLI 80 FJ'S\n51/2x117/\nLVL HOR FLUSH\n11 7/8\" BLI 40 FJ'S\nOPEN FOR\nELEVATOR\n71/2 X 11 7/8\" FLUSH LVL BEAM CONT\n6X8 PARALAM POSTS\nUNDER (2) 7\" wide LVLS\n51/2 X 11 7/8\" FLUSHLVL BEAM CONT\n11 7/8 BLI BO FJ'S\nCONT\n4X6 WD POST ESIDE\n51/2 X 11 7/8\" FLUSH LVL BEAM CONT\n51/2 X 11 7/8\" FLUSH LVL BEAM CONT\nHEAVY DUTY FLUSH HANGERS\nAS PER MFR'S SPECS, TYP\n11 7/8\" BLI 80 FJS\n*(2)2×105 SETS CONT\nCOFFED 12 APARY\n11 7/8 BU 40 FJS\n$1/2 X 11 7/8\" FLUSH LVL BM\nOPEN TO\nFLR ABV\n51/2 X 11 7/8\" FLUSH LVL BEAM CONT\n11 7/8\" BU 80 FJS\nFLUSH LVL BEAM CONT\n■51/2X31-7/8\" FLUSHING HO\n6X6 WD POST ESIDE\nOF THIS UNIT\n4x6 WD POST BTW\nSASH, ESIDE THIS DR\n6X6 WD POST\n3 1/2 X 11 7/8\" FLUSH LVL\n(3)2x10'S\n6X6 PARALAM\n(22X10'S\nWNO POST ES\n4X6 WD POSTS\n3/2 X 11 7/8\" FLUSH LVL HOR\n31/2x117/8\" FLUSH LVL CONTEM\nCARRY CORNER O'HD DOOR HDR INTO\nEXT CORNER W/ 6\" POST BRG, TYP\nTYP EXE WO\nPOSTS ES\n11 7/8\" BLI 80 FJ'S\nOPEN FOR\nSTARWAY\n11 7/8\" BLI 80 FJ'S\nBEAM SET INSIDE ANGLED WALL FMG\nLIMITS (TACK W60 TO TOP FLANGE)\n6X6 PARALAM\nWD POST ESIDE\n3 1/2 X 11 7/8 PLUSHLVL BEAM CONT\n3 1/2 X TY//8\" FLEGREVE TEAST CONT\n11 7/8\" BLI 40 FJS\n51/2 X 11 7/8\" FLUSH LVL BEAM CONT\nNOTE: APPROP STL JST HANGERS\nAT ALL FLUSH FMG COND\n$1/2 X 11 7/8\" FLUSH LVL BEAM CONT\n6\" WALLS FOR PLBG STK\n11 7/8\" BLI 40 FJS\n4XG WD POSTS\nIN WALLS, TYP\nUND\nS1/2 X 11 7/8\" FLUSH\nLVL BEAM CONT\nW8X21 DROPPED STL BM\nLVL HOR FLUSH\nPACK OUT & THRU-BOLT STL BM\nWEBS ESIDE FOR FLUSH FRAMING\n4X6 WD POSTS, TYP\n(2)2X12'S HDR\n11 7/8\" BLI 40 FJ'S\n416 O\nPOSTS\n51/2 X 11/7/8\" FLUSH LVL BEAM CONT\n11 7/8 BL 40 FJ'S\nBRG WALL\nPARALAM POSTS FOR ELEVATOR\nRAIL SUPPORT AS PER SHOP DWGS\n4X6 POST UP/DN IN ELEV\nWALL CORNERS, TYP UND\n11 7/8\" BLI 40 FJ'S\n11 7/8\"\n(2)2X125\nBL-40 FJ'S\n$1/2x91/2 LVL HOR\n4X6 POSTS IN WALL ES\nNOTE: R-38 FGL BATT INSUL INSTALLED\nAT GAME ROOM FLR JST CAVITIES, TYP\n4X6 POSTS IN WALL TYP, UON\n11 7/8\" BU 40 FJS\n11 7/8\" BLI 40 FJ'S\n1/2 X 117/CROPPED LVL BEAM CONT\n100\n51/2 X 11 7/8\" FLUSH LYL BEAM CONT\n6\" WALL FOR PLBG STK\n11 7/8\" BLI 40 FJ'S\n11 7/8\" BLI 40 FJ'S\nNOTE: CONT LVL BM, OR SPLICE @C-LINE\n4x6 COLUMN AS PER MRF'S DETAILG\n(3)2X8'S\n10s 1\naznes\nLVL DROP HOR\n5 1/2 X 11 7/8 FLUSH L\nLVL BEAM CONT\nZXER/S\n51/2 X 117/FLUSH LVL HOR\n32XB'S\n(3)TO'S\n(3)2x8'S\n(3)28'S\nINFILL 2X6 JACKS W/ FLARED\nROOF DET'S TYP\n2X10CJ'S\n51/2 X 11 7/8 RUSHLVL BEAM CONT\n5\n2X6 CJ'S/COFFERED\n2X12 RIDGE POLET\nPOST BTW SASH\n3 1/2 X 11 7/8\" FLUSHLVL BEAM CONT\nCONT\n(3)2X10'S\nCONTHOR\n(3)2X10'S CONT FOR\nANGLED INFILL HDR ABV TRANSOM\nSASH VIF\nINFILL ARCHED SOFFIT FMG TO CURVED\nPROFILE OF DOOR/TRANSOM AS |\n1'-0\"\n12\n12'-0\"+/-\nGAME ROOM\n3 CAR GARAGE\nCROSS SECTION \"B\"\n1/4\" SCALE\n6\" WALL FOR PLBG STK FROM ABV\nBOX OUT DROPPED HDR: SIM MATCH\nTO FAM RM BM WIDTH/DETAIL\n2X4 RECESSED INFILL FMG 18\" WIDE\n2X6 CRICKET FMG ABV, TYP\nCORA-VENT RIDGE VENT W/\nSHINGLE CAP TYP. (MIN.\n1\" AIR SPACE EA. SIDE OF\nRIDGE FOR VENTILATION)\nFIBERGLASS ROOF SHINGLES\nON 15 #FELT OVER 5/8\"\nPLYWOOD SHEATHING\nROOF JOISTS AS PER PLAN\nRIDGE POLE AS PER PLAN\nRIDGE DETAIL \"1\" SCALE 1\" - 1'-0\"\nGARAGE\n5/8\" 1 HR RATED GWB, TAPE/SPACKLE\n6\" STUD WALL AS PER PLAN W/ R-21\nFIBERGLASS INSUL\nSTUCCO/STONE AS OVER TYVEK\nHOUSEWRAP & 1/2\" CDX PLYWOOD\n(2) ZX 6 P. TREATED SILL PLATE W/\n18\" AB 5'-0\" O.C. W/ R-2 SILL SEALER\nCEMENT PLASTER ON BLK. ABV. GRADE\nICE SHIELD\n36\"\nSOFFIT\nPLUS\nOH\nSEE PLAN\nFIBERGLASS ROOF SHINGLES AS PER ELEVATION\nON 15 LB FELT OVER 5/8\" CDX PLYWOOD ROOF\nSHEATHING\nROOF JOISTS AS PER FRAMING PLAN W/TYP\nR-30 BATT CAVITY INSULATION\nPROVIDE MIN. 1\" AIR SPACE OR AIR /BAFFELS ABV\nINSULATION FOR CONT VENTILATION\nICE & WATER SHIELD MEMBRANE\nSIMPSON HURRICANE (H2.5A) CLIPS 16\" O.C.\nOR TECO TRP-L-GRIP EQUAL\nALUM. GUTTER ON AZEK FASCIA ON 2x6\nSUB FASCIA TO MATCH EXST'G\nAZEK SOFFIT (BEAD BOARD) W 2CONT\nSCREENED VENTG STRIP\nAZEK CROWN/TRIM AS\nSTUCCO/STONE FINISH ON TYVEK\nHOUSEWRAP AND 1/2\" CDX PLYWOOD\nWALL SHEATHING\nSTUD WALL AS PER PLAN W/R-15\nBATT INSUL FOR 4\" WALLS AND R-21\nBATT INSUL FOR 6\" WALLS TYP\nROOF/SOFFIT DET.\n\"2\"\nSCALE: 1\"-1'-0\"\nFLARED ROOF EAVE AREAS (SEE ELEVATIONS)\nRP ZX STOCK EXTENSIONS TO ROOFING PROFILE\n(+TWO LAYERS 3/8\nSHEATHING, TYP\nAT EACH FLARE DETAIL)\nNOTE: CARRY ALL POSTS, BRG PTS, & OTHER\nLOADING TO BSMT FON BRG, TYP WHETHER\nINDICATED OR NOT (VIF FMG INSP)\nUNEXCAV\nApprox.\nGrade Sloped\n12\" LOAD BEARING CONC. BLOCK W/\nDURA-WALL EVERY OTHER CSE.\n(GROUT TOP & BOTTOM CSES. SOLD)\nCONC. SLAB AS PER PLAN ON 6 MIL. VB\n& 4\" CRUSHED STONE (4\" PVC FTG/RADON\nPIPE PERIMETER TIED TO BSMT SUMPS)\nCONC. COVE WASH\n24\" x 12\" CONT. CONC. FTG w/ 2X4 KEY\nTHIS DRAWING REMAINS THE PROPERTY OF THE ARCHITECT AND\nITS CONTENTS SHALL NOT BE REPRODUCED WITHOUT WRITTEN\nAUTHORIZATION\nCONTRACTOR MUST VERIFY ALL DIMENSIONS AND CONDITIONS IN\nTHE FIELD, AND SHALL OBTAIN ALL OTHER PROJECT INFORMATION\nNECESSARY TO PERFORM\nUSE NUMERICAL DIMENSIONS FOR CONSTRUCTION PURPOSES\nDO NOT SCALE DRAWING PRINTS\nGROFF RESIDENCE\nNew Custom Residence\nNEW CANAAN, CT\nHeyrich Drake\nJohn Heyrich\nREVISIONS\nNO.\nDATE\nDESCRIPTION\nA\nCheater, NJ 0730\nA\nGAR FDN DETAIL\n\"3\"\nSCALE 1\" 1'-0\"\nassociate architects\nSarah Drake\nBrook, NY 11217\nFRAMING/SECTION\n6\n1231\nJG\n15 AUG 2012\n11\nEFTA00599812\n", "char_count": 6184}]}