From: Pete Rawson Sent: Saturday, April 9, 2016 11:02 PM To: Jeffrey E.; lvjet Subject: Re: Hello Jeffrey, Larry knows that I am long winded with my responses, Here is my brief- Feel free to read all at your leisure- They are mostly my thoughts so far- I suspect that the right precooler (fan air) modulating valve is bad. They are both original. From the last video and Photo's; The readings show that the left side is being given a voltage to th= Torque motor sending a pressure to command the valve to be partially=dosed. Zero volts, zero pressure is for full open, ie: cold air into the precoo=er and lowering the temperature into the supply system. The signals show a steady state condition; 3 Volts, 3 PSI. The valve has been sent signals, and has responded correctly, and theref=re is in the proper position to maintain 400 degrees in the supply system. /p> This is being monitored, and controlled by the controller, and the senso= inputs. EFTA_R1_00087131 EFTA01773967