MODEL: GV-SP (G550) SERIAL NO.: 5070 TAIL NO.: IIB-JEP WORK ORDER NO.: SC9403 • ulfstrearn 0 INSPECTION / MAINTENANCE RECORD FAA CRS EC3R470I. ACTT: 3.053.9 ACTL: 1.022 DATE BEGUN: January 2, 2011 DATE COMPLETED: January 7, 2011 Page 1 of 6 THE FOLLOWING ITEMS WERE ACCOMPLISHED AT GULFSTREAM AEROSPACE CORPORATION, LONG BEACH, CA. UNDER THE ABOVE WORK ORDER NUMBER: 1. Accomplished the following Gulfstream Aerospace Corporation Customer Bulletins (C.B's): a) C.B. No. 88A 'Fire Protection (ATA 26). Inspection - Baggage Compartment Below Floor - Overheat Thermal Switch' b) C.B. No. 103 'Fuselage (ATA 53). Inspection - Fasteners at Fuselage Station 63. Left and Right That Line 19' c) C.B. No. 107 'Landing Gear (ATA 32) Inspection - Door Control Valve Hydraulic Lines' 2. Accomplished the following Rolls-Royce Deutschland Sen ice Bulletins (SB's): a) SB-IIR700-72.900455 Rev. 5 Part A 'Engine - Low Pressure (U') Compressor Blacks - Visual Inspection of the LP Compressor Annulus Fillers' b) SB-BR700-72-900455 Rev. 5 Pan I3 'Engine - Low Pressure (LP) Compressor Blades - Eddy Current Inspection of the LP Compressor Annulus Fillers' c) SB-BR700-78-900350 'Exhaust-Thrust Reverser Unit (TRU) - Inspection of the Spherical Bearing of the Primary Door Lock Actuator (PDIA) and Cleaning of the S-Hook Assembly. Non Modification' 3. Accomplished the following Gulfstrcam Aerospace Corporation 500 Hrs CMP codes: CMP CODE DESCRIPTION 4934°2 APU FUEL FILTER BYPASS INDICATOR-INSPECTION 494°°2 APU Starter • Detailed Inspection 4°8°81 APU EXHAUST DUCT (INT),INSPECT 4. Accomplished the folkwitt>z Gulfstre CMP CODE DESCRIPTION 342111 Integrated Drive Gents (Left) - Detailed Inspection 242112 Integrated Dent Generator (Right) - Detailed Inspection 242115 Integrated Drive Generator (Left) - Servicing 242116 Integrated Drive Generator (Sight) • Servicing 275019 Flap Actuator Trawl Nut (Len) - Lubrication 275020 Flap Actuator Travel Nut